Apply to be a TradeMaster!
Main product image of Aquastat Relay, 8-Degree(F) Differential, L8148J1009
Magnifying glass
Hover image to zoom

Aquastat Relay, 8-Degree(F) Differential, L8148J1009

Brand:
Resideo
SKU:
L8148J1009
Rating:
(72)
Q&A:
(15)
Aquastat Relay, 8-Degree(F) Differential, L8148J1009
Magnifying glass
Hover image to zoom
$368.14 each
In Stock
In Stock
Get 64 Tue, Aug 18
Order by today, receive Tuesday
Free Shipping This item ships free
Easy Returns No restocking fee for 90 days

Product Highlights

Product Highlight: Electrical Rating
Burner: 7.4 A @ 120 Vac, Burner: 3.7 A @ 240 Vac, Circulator: 7.4 A @ 120 Vac, 0.25 A @ 0.25 to 12 Vdc, Circulator: 3.7 A @ 240 Vac
Product Highlight: Differential
Fixed, 8°F
Product Highlight: Switch Action
SPST
Product Highlight: Mount
Horizontal, Vertical
Product Highlight: Temperature Range (F)
120°F to 240°F
Product Highlight: Height
6-1/8"

Description

Immersion-type controllers that combine high limit protection with switching relay control of burner and circulator motors.

Features
  • High limit opens burner circuit only.
  • Include transformer and accessory terminals for adding a remote low limit controller.
  • Case available for horizontal or vertical mounting.
  • Requires a 24 Vac thermostat with heat anticipator set at 0.2A.
  • Specs

    Frequency:

    60 Hz

    60 Hz

    60 Hz

    Application:

    High Limit

    Switch Action:

    SPST

    Electrical Rating:

    Burner: 7.4 A @ 120 Vac

    Burner: 3.7 A @ 240 Vac

    Circulator: 7.4 A @ 120 Vac

    0.25 A @ 0.25 to 12 Vdc

    Circulator: 3.7 A @ 240 Vac

    Electrical Ratings (ALR):

    Burner: 22.2 A @ 240 Vac

    Circulator: 44.4 A @ 120 Vac

    Burner: 44.4 A @ 120 Vac

    Circulator: 22.2 A @ 240 Vac

    Temperature Range (F):

    120°F to 240°F

    Differential:

    Fixed

    8°F

    Height:

    6-1/8"

    Width:

    4-3/8"

    Depth (Inches):

    3-1/8"

    Operating Humidity:

    0% to 95% (non-condensing)

    Mount:

    Horizontal

    Vertical

    Max Ambient Temp (°F):

    150F with 1.2A 24V Load

    77F with 1.4A 24V Load

    Connection Type:

    Quick-Connect

    Capillary Length:

    4-1/2"

    Anticipator Rating:

    0.2 A

    Voltage:

    120v

    Max Pressure (PSI):

    255 (Immersion Well)

    Contact

    Help Face
    CALL US
    Question? Call or text 888-757-4774
    +
    Help Face

    Questions?

    Speak with a real person who will go out of the way to help!
    Call or text 888-757-4774
    MondayThursday
    8am7:45pm
    Friday
    9am7:45pm
    SaturdaySunday
    9am5:45pm


    You May Also Need

    Product Reviews

    4.57 out of 72 reviews
    97% would recommend this product
    4.57
    out of 72 Reviews
    97% would recommend this product
    WRITE A REVIEW
    5 star
    83%
    4 star
    3%
    3 star
    6%
    2 star
    4%
    1 star
    4%
    WRITE A REVIEW
    Customer Images

    Most Liked Positive Review

    Works perfectly

    A friend of mine and his son installed it with no problems. It replaced an older version of the same unit.
    VS

    Most Liked Negative Review

    Room for improvement

    Transformer quality sub-par. I had a situation where there were 3 surge events and this units transformer was the only one that blew out 3 times. I wish there was a competitor.
    Showing 1-10 of 72 reviews

    Works as it should

    Used this to replace my original aquastat. Seems to be working fine. I'll add the schematic I used to wire my two zones except my zone valves use black wires instead of yellow but it is the same.
    Mo
    Macomb, MI
    1 years ago
    Was this review helpful to you?

    Satisfied customer.

    Product was shipped and received in a timely manner. Price was appropriate.
    Alan
    Colorado
    1 years ago
    Verified Buyer Icon
    Verified Buyer
    Was this review helpful to you?

    Customer Service 5* product 0*

    I ordered this aquastat to replace on that had been in service less than a year, but the transformer failed. I installed the new one and the transformer also didn't work. I filled out the replacement form and Supply House sent the replacement no questions asked. The replacement works just fine. Obviously this is a consistent problem with the equipment from the manufacturer.
    Disappointed
    Colorado
    2 years ago
    Verified Buyer Icon
    Verified Buyer
    Was this review helpful to you?

    Perfect

    The boiler that I was looking at had a runaway temperature occurring. And in which I did the necessary research to discover that it was the aquastat that went bad. Ordered the correct one and now works exactly like it's supposed to.
    Noob
    Illinois
    2 years ago
    Verified Buyer Icon
    Verified Buyer
    Was this review helpful to you?

    Product was trash but SupplyHouse gets full marks

    Resideo products were trash (I tried three of them and none worked) but SupplyHouse gets five stars for exemplary customer service.
    Jerry
    Otsego, Michigan
    2 years ago
    Verified Buyer Icon
    Verified Buyer
    Was this review helpful to you?

    Aquastat L8148J failed after 3 years

    Aquastat L8148J started to make noise after 3 years then failed
    ben
    Edison NJ
    3 years ago
    Was this review helpful to you?

    Third failure in 6 years

    Unfortunately my 8184J just failed for the third tim in 6 years. Each time is the same symptom, the circulator fails to power on when heat is called. The first two failures I replaced with new units, suspecting bad solder joints. This time I discovered that the issue was the solder joints, specifically C1. I was able to re-solder C1 and return the unit service.
    ken
    NY
    3 years ago
    Was this review helpful to you?

    Not a direct replacement as advertised.

    While this product can be configured to work in a number of applications. It is not a direct replacement as advertised. Knowledge beyond that provided in the instructions is required to properly configure the device for your specific application. If you are buying this thinking it will be a plug and play, you may be disappointed.
    Matt
    Fife Lake, MI
    3 years ago
    Verified Buyer Icon
    Verified Buyer
    Was this review helpful to you?

    Awsome

    Easy to install. Works as described
    Nate
    Ohio
    3 years ago
    Verified Buyer Icon
    Verified Buyer
    Was this review helpful to you?

    Aquastat Relay is great!

    The Aquastat Relay is great, however, getting it to us was not! The system should not update at 10 PM and say the item will be received the next day. Our first item was lost, I called Customer Service on Friday and was told I had to wait 24-72 hours for the system to update. I called again on Monday when the system was still saying only the label was created for the first item. Mia was amazing, she exemplifies GREAT customer service. She stayed on the line until a solution was made. She made sure another item was shipped and we received that two days later, even though again, at 10 PM the system said we would get it the next day. It would have been much quicker to drive to pick it up than to wait a week with no heat!
    Sassyyy
    Maryland
    3 years ago
    Verified Buyer Icon
    Verified Buyer
    Was this review helpful to you?

    Product Q&A

    15 Questions
    15 Questions
    ASK A QUESTION

    Q: Is it recommended to change the immersion well at the same time as replacement of the aquastat, L8148J1009, and if so what is the correct replacement # to use +

    Asked by george 16 years ago

    Add your answer

    * Required Field
    Verified Author and ReplyVerified Reply- PexSupply Staff

    Yes, it is recommended. For a ½” well, use part 121371A , and use part 121371B with ¾” wells.

    Was this review helpful to you?

    Q: will this replace L8048E need to replace

    Asked by Dave 16 years ago

    Add your answer

    * Required Field
    Verified Author and ReplyVerified Reply- PexSupply Staff

    As per Honeywell, the following relays can be replaced by the L8148J1009: L8048E1027, L8048E1035, L8048E1043, L8048E1076, L8048E1092, L8048E1K0A, and L8048E2K0A.

    Was this review helpful to you?

    Q: I just had my Honeywell Aquastat Relay L8148E replaced with the L8148J. Apparently this is the direct replacement since the L8148E is discontinued (according to the Honeywell web site). The boiler comes with the automatic vent damper. My HVAC guy replaced the Aquastat and connected the wires just like the old one. However the boiler did not work properly. Even when the thermostat did not call for heat the boiler would still turn on. After some trouble shooting, my HVAC guy told me that it appears that the new Relay L8148J must have some internal ground, and the ground (green wire) that goes from the burner (screwed on the burner) to the GDN (Burner) on the Module (black box on the boiler) was causing this problem. When he disconnected the green wire (GDN burner) everything seems to work just fine. Is this true? Do the L8148J have some internal grounding that would cause this problem. The person in Colorado (see above) appears to have the same problem.

    Asked by sb 16 years ago

    Add your answer

    * Required Field
    Verified Author and ReplyVerified Reply- PexSupply Staff

    The L8148E is still available with a vent damper plug. If you are experiencing issues with the L8148J that was installed, we recommend replacing it with either the L8148E1257 or the L8148E1265, both which are still available.

    Was this review helpful to you?

    Q: Can Aquastat relay L8148J replace Aquastat relay L8148E? Our plumber told the electrician it was OK to take out the L8148E and replace it with the L8148J. They are working on it now and have high over heating and high pressure and trouble shooting. Adjusting the temp indicator does not have any effect, temp just keeps going up super high. A licensed/union plumber and licensed/union electrician. They thought it would be no problem, since they had the aquastat L8148J on hand. I think they need to get the exact model# aquastat that they took out.

    Asked by Liz 16 years ago

    Add your answer

    * Required Field
    Verified Author and ReplyVerified Reply- PexSupply Staff

    The difference between the units is that the "E" model has an operating range of 180 to 240 degrees and a temperature differential of 15 degrees, while the "J" model has an operating range of 120 to 240 degrees and a temperature differential of 8 degrees. It sounds like some temperature setting may need to be changed.

    Was this review helpful to you?

    Q: Is your Honeywell L8148J1009 a replacement for L8148J

    Asked by [email protected] 16 years ago

    Add your answer

    * Required Field
    Verified Author and ReplyVerified Reply- PexSupply Staff

    Yes, SKU # L8148J1009 is the replacement unit for SKU #L8148J.

    Was this review helpful to you?
    Free Shipping
    On orders over $99
    We offer flexible shipping and scheduling options, up-to-date delivery estimates, and free ground shipping on any order over $99 to make sure your order gets to you on-time, for less.
    Shipping Policy
    Easy Returns
    Returning items is as simple as 1-2-3
    Ordered the wrong product? Item damaged in transit? Our 3-step process makes returning products easy – even up to a year after purchase – with no restocking fees on returns made within 90 days.
    Return Policy