| Frequency: | 60 Hz 60 Hz 60 Hz |
|---|---|
| Application: | High Limit |
| Switch Action: | SPST |
| Electrical Rating: | Burner: 7.4 A @ 120 Vac Burner: 3.7 A @ 240 Vac Circulator: 7.4 A @ 120 Vac 0.25 A @ 0.25 to 12 Vdc Circulator: 3.7 A @ 240 Vac |
| Electrical Ratings (ALR): | Burner: 22.2 A @ 240 Vac Circulator: 44.4 A @ 120 Vac Burner: 44.4 A @ 120 Vac Circulator: 22.2 A @ 240 Vac |
| Temperature Range (F): | 120°F to 240°F |
| Differential: | Fixed 8°F |
| Height: | 6-1/8" |
| Width: | 4-3/8" |
| Depth (Inches): | 3-1/8" |
| Operating Humidity: | 0% to 95% (non-condensing) |
| Mount: | Horizontal Vertical |
| Max Ambient Temp (°F): | 150F with 1.2A 24V Load 77F with 1.4A 24V Load |
| Connection Type: | Quick-Connect |
| Capillary Length: | 4-1/2" |
| Anticipator Rating: | 0.2 A |
| Voltage: | 120v |
| Max Pressure (PSI): | 255 (Immersion Well) |
Yes, it is recommended. For a ½” well, use part 121371A , and use part 121371B with ¾” wells.
As per Honeywell, the following relays can be replaced by the L8148J1009: L8048E1027, L8048E1035, L8048E1043, L8048E1076, L8048E1092, L8048E1K0A, and L8048E2K0A.
The L8148E is still available with a vent damper plug. If you are experiencing issues with the L8148J that was installed, we recommend replacing it with either the L8148E1257 or the L8148E1265, both which are still available.
The difference between the units is that the "E" model has an operating range of 180 to 240 degrees and a temperature differential of 15 degrees, while the "J" model has an operating range of 120 to 240 degrees and a temperature differential of 8 degrees. It sounds like some temperature setting may need to be changed.
Yes, SKU # L8148J1009 is the replacement unit for SKU #L8148J.