Round Motorized Dampers are 24V galvanized steel round dampers from Aprilaire for zoning and ventilation jobs. Aprilaire says its round dampers work with either rigid metal or flex duct. The 6 inch ventilation damper is normally closed and power open, while the 18 inch zone damper and the 4, 5, and 6 inch automatic slip-in dampers are normally open and power close. The descriptions for the 6 inch ventilation damper and 18 inch zone damper list a 24Vac, 6W, 19VA, 60Hz synchronous motor that is impedance protected for continuous stall. Spring and power action matters because the spring action sets the damper position when power is not applied. Aprilaire positions its slip-in dampers as a way to zone a home without costly duct modification. Knowing the normal position before ordering keeps the zone layout and the control strategy in agreement.
Subcategories
Buying Guide
Start with duct diameter and damper style. Examples include a 4 inch slip-in damper and an 18 inch zone damper, and Aprilaire describes its slip-in line as offered in 4, 5, 6, 7, 8, and 10 inch diameters. Match the damper to the actual round duct size before anything else.
Next, choose the normal position. Within Round Motorized Dampers, a normally open, power close damper opens by spring and closes when powered, while the 6 inch ventilation model is normally closed and power open. Pick the action that matches how the zone or vent should behave when power is not applied.
Then check the electrical and wiring details. The models described here are 24V, and the 6 inch ventilation and 18 inch zone damper descriptions list 24Vac, 6W, 19VA with two wire installation. Confirm the transformer and control capacity can carry the load of every damper on the system before ordering.
Finally, consider the duct type and blade setup. Aprilaire says its round dampers work with rigid metal or flex duct, and the ventilation and zone models describe adjustable blade positioning, a foam seal, and an adjustable stop. Compare those features to the job, and verify fit against the product listing before buying, since position, size, and function differ by model.
Frequently Asked Questions
What voltage do round motorized dampers use?
The Aprilaire round motorized dampers described here are rated 24V. The 6 inch ventilation damper and 18 inch zone damper list a 24Vac, 6W, 19VA, 60Hz synchronous motor. Check each listing for the exact electrical details of the model needed.
What does normally open, power close mean on a round motorized damper?
On a round motorized damper such as the 18 inch Round Zone Damper, normally open and power close means the damper opens by spring and closes when powered. The listing describes this as power close/spring open operation. The 6 inch ventilation damper works the opposite way, with power open and spring close operation.
Do round motorized dampers work with flex duct?
Aprilaire says its round dampers work well with either rigid metal or flex duct. Round motorized dampers in this category are described as galvanized steel. Verify the duct type and size against the listing before installing.
What sizes do round slip-in dampers come in?
Aprilaire describes its round slip-in damper as offered in 4, 5, 6, 7, 8, and 10 inch diameters. The 4, 5, and 6 inch models in this category are normally open and power close. Round motorized dampers of other types carry their own sizes, such as the 18 inch zone damper.
How many wires do these round motorized dampers need?
The 6 inch ventilation damper and 18 inch zone damper descriptions list two wire installation. The same descriptions list an adjustable stop, in the open position for the ventilation damper and in the closed position for the zone damper. Confirm the wiring details for any other round motorized damper on its listing.