Watts 709 Double Check Detector Assemblies are backflow prevention devices built for fire protection systems that also need to detect unauthorized water use or ongoing leaks. The assembly carries a maximum working pressure of 175 psi and uses a cast iron body with the ArmorTek epoxy coating system to resist corrosion from both microbial activity and exposed metal substrate. A bypass meter runs parallel to the main check valves, registering any flow through the system so a facility can catch a leaking pipe or an illegal tap before it turns into a larger water loss problem. Sizes from 3 inch through 8 inch cover fire protection mains from small commercial buildings up to large industrial systems. Water utilities require this kind of detector assembly on any fire line tied into the potable supply, which makes correctly sizing and specifying the 709 essential to passing inspection and keeping the fire system compliant.
Subcategories
Buying Guide
Sizing a double check detector assembly starts with the fire protection system's calculated flow demand, not the size of the incoming water main. An undersized assembly creates unacceptable pressure loss across the fire system, while an oversized one adds unnecessary installation complexity. Watts 709 Double Check Detector Assemblies cover that range with 3 inch, 4 inch, 6 inch, and 8 inch options, so match the size to the hydraulic calculations already required for sprinkler system design rather than defaulting to the size of the existing main. Working pressure stays constant across the line at 175 psi maximum, so confirm the system's static and residual pressure stays within that limit before specifying a model. Body construction matters for long-term reliability: cast iron with the ArmorTek epoxy coating resists both microbial induced corrosion and damage from exposed metal substrate, which extends service life in wet, below-grade vaults where these assemblies commonly sit. The bypass meter isn't optional in most jurisdictions, since local water authorities typically require it to detect illegal taps and ground leaks on any fire line connected to the potable supply. Confirming with the local water authority whether a cubic feet meter or gallons per minute meter is required matters too, since jurisdictions differ on which reading format they accept for compliance reporting. Getting the meter type wrong at order time means a return trip before inspection.
Frequently Asked Questions
What sizes does the Watts 709 come in?
The Watts 709 comes in 3 inch, 4 inch, 6 inch, and 8 inch configurations to match fire protection mains of different flow demands. Sizing follows the sprinkler system's hydraulic calculations rather than the size of the incoming water main. Each size shares the same 175 psi maximum working pressure rating.
What is the maximum working pressure of the Watts 709 assembly?
The Watts 709 Double Check Detector Assembly carries a maximum working pressure of 175 psi across every size in the line. Confirming that the fire protection system's static and residual pressure stays within that limit is part of the specification process. Pressure rating stays the same regardless of assembly size.
What does the bypass meter on a 709 detect?
The bypass meter registers any flow moving through the assembly outside normal fire system operation, which flags illegal taps or ground leaks on the line. Local water authorities typically require this feature on fire lines connected to the potable supply. The meter is available in cubic feet or gallons per minute formats depending on what the local authority accepts.
What protects the Watts 709 body from corrosion?
A cast iron body coated with the ArmorTek epoxy system protects the Watts 709 from both microbial induced corrosion and damage from exposed metal substrate. The coating matters most in wet, below-grade vaults where these assemblies typically sit. Corrosion protection is consistent across all sizes in the 709 line.
Why does a fire protection system need a double check detector assembly instead of a standard backflow preventer?
A double check detector assembly adds a bypass meter that a standard backflow preventer doesn't have, allowing detection of illegal taps and ground leaks on a fire protection line. Water utilities require this detection capability on fire mains connected to the potable water supply. The Watts 709 line provides that function across 3 inch through 8 inch sizes while still preventing backflow of non-health hazard substances into the potable system.