Apply to be a TradeMaster!
Filter menu expanded

Filters

471,064 items
Reset

SORT

Wilo Top S Pump Parts

Help Face
Need a little help?
471064 items
Grid
List
Compare
Product Image of Nut Steel 5/8"-11unc He
Nut Steel 5/8"-11unc He
SKU: 913229-900
Armstrong Pumps
SKU: 913229-900
$6.23 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Compare
Product Image of Burner 140m 7250p-043 Pi, 91408
$1,963.80 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Compare
Product Image of Condenser Air Iceu, 9141126-01
Condenser Air Iceu, 9141126-01
SKU: 9141126-01
Ice-O-Matic
SKU: 9141126-01
Brand: Ice-O-Matic
$830.12 each
In Stock
Get 3 by Tue, Dec 1
In Stock
Get 3 by Tue, Dec 1
Compare
Product Image of Cylinder 15" 2 Light Wall Light (Brushed Aluminum)
$155.95 each
Out of Stock
Get it by Mon, Dec 14 - Mon, Dec 21
Out of Stock
Get it by Mon, Dec 14 - Mon, Dec 21
Compare
Product Image of 2" Gromet for WCR-9SP
2" Gromet for WCR-9SP
SKU: 925033
Little Giant
SKU: 925033
Brand: Little Giant
$25.32 each
Out of Stock
Get it by Mon, Dec 14 - Mon, Dec 21
Out of Stock
Get it by Mon, Dec 14 - Mon, Dec 21
Compare
Product Image of Evaporator Coil Assembly Trcb-36 w/ contr, 925140
$683.94 each
Out of Stock
Get it by Mon, Dec 14 - Mon, Dec 21
Out of Stock
Get it by Mon, Dec 14 - Mon, Dec 21
Compare
Product Image of Harness Ebm Blwr Cable Molex, 91436
$322.41 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Compare
Product Image of Insert A for 9144 Dry-Well Calibrator (Assorted Imperial Holes), 9144-INSA
$996.64 each
In Stock
Get 1 by Wed, Dec 2 - Thu, Dec 3
In Stock
Get 1 by Wed, Dec 2 - Thu, Dec 3
Compare
Product Image of SPST 110/120V General Purpose Switching Relay
$18.06 each
In Stock
Get 1 by Thu, Dec 3
In Stock
Get 1 by Thu, Dec 3
Compare
Product Image of 9230-611 Parts - Coleman Heat Pumpnot-to-sell-product
9230-611 Parts - Coleman Heat Pump
SKU: 9230-611
Coleman
SKU: 9230-611
Brand: Coleman
Backorder
Get it by Mon, Jan 4 - Wed, Feb 3
Backorder
Get it by Mon, Jan 4 - Wed, Feb 3
Compare
Product Image of Ring-rtng Ext Stainless Steel 19/32"d
$33.34 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Compare
Product Image of Insert D for 9143 Dry-Well Calibrator (Metric Comparison Holes), 9143-INSD
$1,080.20 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Compare
Product Image of Boot Blwr Outlet Press Tap, 91446
$13.97 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Compare
Product Image of Coupling 2 Pvc Htp#n122, 91453
$16.09 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Compare
Product Image of Coupling 3 Pvc Htp#ni121, 91466
$73.10 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Compare
Product Image of Vent Term Kit Concentric 2", 91469
$222.03 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Compare
Product Image of Evaporator Coil Assembly Trcb-82 906445, 914921
$1,345.03 each
Out of Stock
Get it by Mon, Dec 14 - Mon, Dec 21
Out of Stock
Get it by Mon, Dec 14 - Mon, Dec 21
Compare
Product Image of Software P125 Service, 91490
$23.68 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Compare
Product Image of 915-4E3.0S/P6785842R Parts - Amana Air Conditionernot-to-sell-product
915-4E3.0S/P6785842R Parts - Amana Air Conditioner
SKU: 915-4E3.0S/P6785842R
Goodman-Amana
SKU: 915-4E3.0S/P6785842R
Out of Stock
Get it by Mon, Dec 14 - Mon, Dec 21
Out of Stock
Get it by Mon, Dec 14 - Mon, Dec 21
Compare
Product Image of Coil Solenoid Valve 208-240V, 9151193-02
$77.33 each
In Stock
Get 10 by Tue, Dec 1
In Stock
Get 10 by Tue, Dec 1
Compare
Product Image of Studbolt Steel 1/2" X 6
Studbolt Steel 1/2" X 6
SKU: 915125-548
Armstrong Pumps
SKU: 915125-548
$13.79 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Compare
Product Image of 11/16" x 55-1/2" Shaft, 92325514
11/16" x 55-1/2" Shaft, 92325514
SKU: 92325514
PennBarry
SKU: 92325514
Brand: PennBarry
$920.69 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Compare
Product Image of 9236-913 Parts - Coleman Heat Pumpnot-to-sell-product
9236-913 Parts - Coleman Heat Pump
SKU: 9236-913
Coleman
SKU: 9236-913
Brand: Coleman
Backorder
Get it by Mon, Jan 4 - Wed, Feb 3
Backorder
Get it by Mon, Jan 4 - Wed, Feb 3
Compare
Product Image of 9248-913 Parts - Coleman Heat Pumpnot-to-sell-product
9248-913 Parts - Coleman Heat Pump
SKU: 9248-913
Coleman
SKU: 9248-913
Brand: Coleman
Backorder
Get it by Mon, Jan 4 - Wed, Feb 3
Backorder
Get it by Mon, Jan 4 - Wed, Feb 3
Compare
Product Image of 926TC60080V21A-A Parts - Carrier Preferred 96% AFUE Two-Stage Gas Furnacenot-to-sell-product
Backorder
Get it by Fri, Feb 26 - Fri, May 21
Backorder
Get it by Fri, Feb 26 - Fri, May 21
Compare
Product Image of Washer Steel 3/8" W
Washer Steel 3/8" W
SKU: 927114-100
Armstrong Pumps
SKU: 927114-100
$4.15 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Compare
Product Image of QC7I Twin Parallel Head
QC7I Twin Parallel Head
SKU: 9272-22
Nu-Calgon
SKU: 9272-22
Brand: Nu-Calgon
$686.79 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Compare
Product Image of 24" x 24" Preassembled Grinder Pump System w/ M807, 1 HP, 115V Pump and Alarm
$1,915.41 each
Backorder
Get it by Mon, Jan 4 - Wed, Feb 3
Backorder
Get it by Mon, Jan 4 - Wed, Feb 3
Compare
Product Image of Coil Solenoid Valve 110-120V, 9151193-01
$53.61 each
In Stock
Get 5 by Tue, Dec 1
In Stock
Get 5 by Tue, Dec 1
Compare
Product Image of Harness Wire 120v Alarm, 91522
Harness Wire 120v Alarm, 91522
SKU: 91522-PEERLESS
Peerless Boilers
SKU: 91522-PEERLESS
$13.97 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Gvl Pi-199 7250p-452, 91540
SKU: 91540-PEERLESS
Peerless Boilers
SKU: 91540-PEERLESS
$1,038.41 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Compare
Product Image of 9154HE40A/P6841310R Parts - Amana Air Conditionernot-to-sell-product
9154HE40A/P6841310R Parts - Amana Air Conditioner
SKU: 9154HE40A/P6841310R
Goodman-Amana
SKU: 9154HE40A/P6841310R
Out of Stock
Get it by Mon, Dec 14 - Mon, Dec 21
Out of Stock
Get it by Mon, Dec 14 - Mon, Dec 21
Compare
Product Image of Burner Nit Pi-80 Rev2, 91553
$1,737.81 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Compare
Product Image of Capillary Tube .052 Id X 100 Ft
Capillary Tube .052 Id X 100 Ft
SKU: BC3-100
Supco
SKU: BC3-100
Brand: Supco
$120.83 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Compare
Product Image of 1.5-Man Bucket Cover
1.5-Man Bucket Cover
SKU: BC523C
Klein Tools
SKU: BC523C
Brand: Klein Tools
$256.75 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Compare
Product Image of Nose Bag, S-Hook, BC534S
Nose Bag, S-Hook, BC534S
SKU: BC534S
Klein Tools
SKU: BC534S
Brand: Klein Tools
$199.99 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Compare
Product Image of 3" FPM Replacement Gasket for Bulkhead Fittings, BFXAGST030F
$86.49 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Compare
Product Image of 1/2" x 5-1/2" Schedule 80 Heavy Duty Black Nipple
1/2" x 5-1/2" Schedule 80 Heavy Duty Black Nipple
SKU: BLNH050-550
Bluefin
SKU: BLNH050-550
Brand: Bluefin
$2.70 each
BOX UP & SAVE 25%
$50.75 box of 25
$2.03 each
In Stock
Get 4 by Mon, Nov 30
In Stock
Get 4 by Mon, Nov 30
Compare
Product Image of Self-Piercing Needle Valve Kit w/ Inserts & Delrin Sleeve
$36.56 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Compare
Product Image of BCA24TA002A/P1177202C Parts - Amana Air Handlernot-to-sell-product
BCA24TA002A/P1177202C Parts - Amana Air Handler
SKU: BCA24TA002A/P1177202C
Goodman-Amana
SKU: BCA24TA002A/P1177202C
Backorder
Get it by Mon, Jan 4 - Wed, Feb 3
Backorder
Get it by Mon, Jan 4 - Wed, Feb 3
Compare
Product Image of BCA30TA002A/P1177203C Parts - Amana Air Handlernot-to-sell-product
BCA30TA002A/P1177203C Parts - Amana Air Handler
SKU: BCA30TA002A/P1177203C
Goodman-Amana
SKU: BCA30TA002A/P1177203C
Backorder
Get it by Mon, Jan 4 - Wed, Feb 3
Backorder
Get it by Mon, Jan 4 - Wed, Feb 3
Compare
Product Image of BCAA24C002A/P1102002C Parts - Amana Air Handlernot-to-sell-product
BCAA24C002A/P1102002C Parts - Amana Air Handler
SKU: BCAA24C002A/P1102002C
Goodman-Amana
SKU: BCAA24C002A/P1102002C
Backorder
Get it by Mon, Jan 4 - Wed, Feb 3
Backorder
Get it by Mon, Jan 4 - Wed, Feb 3
Compare
Product Image of BCCB-T036AC Parts - Coleman Heat Pumpnot-to-sell-product
BCCB-T036AC Parts - Coleman Heat Pump
SKU: BCCB-T036AC
Coleman
SKU: BCCB-T036AC
Brand: Coleman
Backorder
Get it by Mon, Jan 4 - Wed, Feb 3
Backorder
Get it by Mon, Jan 4 - Wed, Feb 3
Compare
Product Image of 1 Pole, 10 to 14 AWG, 600 Volts AC/DC, 15 Amp, DIN Rail Mount Fuse Block 3" Long x 0.86" Wide x 1.22" High Block
$17.61 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Compare
Product Image of 3 Pole, 14 to 6 AWG, 480 Volts AC/DC, 30 Amp, DIN Rail Mount Fuse Block 3" Long x 2.38" Wide x 1.22" High Block
$196.20 each
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Backorder
Get it by Wed, Dec 30 - Fri, Jan 29
Compare
Product Image of BGD10020AX Parts - Coleman Furnacenot-to-sell-product
BGD10020AX Parts - Coleman Furnace
SKU: BGD10020AX
Coleman
SKU: BGD10020AX
Brand: Coleman
Backorder
Get it by Mon, Jan 4 - Wed, Feb 3
Backorder
Get it by Mon, Jan 4 - Wed, Feb 3
Compare
Product Image of BCCB-W036AC Parts - Coleman Heat Pumpnot-to-sell-product
BCCB-W036AC Parts - Coleman Heat Pump
SKU: BCCB-W036AC
Coleman
SKU: BCCB-W036AC
Brand: Coleman
Backorder
Get it by Mon, Jan 4 - Wed, Feb 3
Backorder
Get it by Mon, Jan 4 - Wed, Feb 3
Compare
Product Image of BCCB-W048AC Parts - Coleman Heat Pumpnot-to-sell-product
BCCB-W048AC Parts - Coleman Heat Pump
SKU: BCCB-W048AC
Coleman
SKU: BCCB-W048AC
Brand: Coleman
Backorder
Get it by Mon, Jan 4 - Wed, Feb 3
Backorder
Get it by Mon, Jan 4 - Wed, Feb 3
Resources
FAQs, Manuals & Videos
Articles
More About Wilo Top S Pump Parts

Wilo Top S pump parts keep the Wilo Top S line of hydronic circulator pumps running in residential and light commercial heating and cooling systems. Wilo Top S circulators move hot or chilled water through hydronic piping in boiler, radiant, and fan coil applications, and replacement parts extend the service life of pumps already installed in the field. Common parts include motor cartridges, seal kits, gaskets, and control modules that wear or fail well before the pump housing itself needs replacement. Technicians servicing a Wilo Top S pump typically diagnose whether the issue is electrical, mechanical, or related to a worn wet end before ordering parts. Stocking the right cartridge and seal combination for a given pump size shortens repair time on a callback. Sourcing genuine Wilo replacement parts helps maintain the pump's original flow and efficiency performance rather than settling for a full pump swap.

Subcategories

  • Motor Cartridges: Motor cartridges contain the wet-rotor motor assembly that drives the pump impeller. Technicians replace a cartridge when the motor windings fail or bearings wear out, since the cartridge can typically be swapped without removing the pump body from the piping. Matching cartridge voltage and pump size to the installed housing is essential for proper fit. Replacing the cartridge alone is usually faster and less disruptive than replacing the entire pump.
  • Seal and Gasket Kits: Seal and gasket kits address leaks at the pump housing and cartridge interface, a common failure point in circulators that run continuously through a heating season. Technicians inspect for mineral buildup or a hardened gasket before assuming the pump body itself is damaged. Replacing seals proactively during scheduled maintenance can prevent a leak from becoming a no-heat emergency call. Kits are sized to match specific Wilo Top S pump models.
  • Control Modules: Control modules on variable-speed Wilo Top S pumps manage speed settings and communicate operating status. A failed module often causes the pump to run at a fixed speed or stop responding to system demand. Technicians troubleshoot wiring and power supply before replacing a module outright. Choosing the correct module version for the pump's control type avoids compatibility issues.
  • Flanges and Mounting Hardware: Flanges and mounting hardware connect the Wilo Top S pump body to the system piping and support proper alignment. Worn or corroded flange gaskets are a frequent source of slow leaks around the pump connection points. Technicians replace flange hardware during a full pump service to prevent recurring leaks. Correct flange sizing keeps the pump properly aligned with existing piping runs.
  • Buying Guide

    Ordering the correct Wilo Top S pump parts starts with confirming the exact pump model and voltage printed on the unit's nameplate, since cartridges and control modules are not interchangeable across the full Top S lineup. Technicians should determine whether the pump uses a fixed-speed or variable-speed motor cartridge before ordering a replacement, since installing the wrong type can leave the system without proper speed control. When a pump is leaking, checking whether the failure is at the seal, the gasket, or a cracked housing helps determine whether a seal kit will resolve the issue or a full cartridge or pump replacement is needed. For control modules, confirming the communication protocol the building automation system expects prevents a mismatch between the new module and existing controls. Contractors stocking Wilo Top S pump parts for commercial service routes often keep cartridges and seal kits on hand for the pump sizes most common in their service area, since hydronic systems can fail without much warning during cold weather. Reviewing the pump's original installation documentation, when available, helps confirm the exact part numbers needed and reduces the chance of ordering an incompatible component. Replacing worn parts on a Wilo Top S pump promptly, rather than waiting for a full failure, typically costs less in labor than an emergency pump swap during peak heating season.

    Frequently Asked Questions

    Can a Wilo Top S motor cartridge be replaced without draining the whole system?

    Most Wilo Top S pumps allow the cartridge to be removed while isolating the pump with flange-mounted isolation valves, limiting water loss to the pump body itself. Systems without isolation valves will require draining before cartridge replacement. Checking for isolation valves ahead of the service call helps technicians plan the repair more efficiently.

    What typically causes a Wilo Top S pump to run noisy?

    Noise often points to air trapped in the system, a worn bearing inside the motor cartridge, or debris caught in the impeller. Bleeding air from the system is usually the first troubleshooting step before replacing any parts. Persistent grinding or humming after bleeding usually indicates a cartridge replacement is needed.

    How do I identify the correct replacement seal kit for a Wilo Top S pump?

    The pump's model number and size, found on the nameplate, determine the correct seal kit, since kits vary by pump body size. Technicians should record this information before removing the pump for service. Ordering by nameplate model number avoids fit issues with the wrong kit.

    Why would a variable-speed Wilo Top S pump stop responding to a building automation system?

    A failed or disconnected control module is a common cause, along with wiring faults at the communication terminals. Technicians should verify power and signal wiring before replacing the module. Confirming the module's communication protocol matches the automation system prevents recurring issues after replacement.

    Is it possible to upgrade a fixed-speed Wilo Top S pump to variable-speed using replacement parts?

    Fixed-speed and variable-speed Wilo Top S pumps use different motor cartridges and control architectures, so an upgrade generally requires a cartridge designed for variable-speed operation along with a compatible control module. Confirming the pump housing supports the variable-speed cartridge is an important step before ordering parts. Contractors should check manufacturer documentation to confirm compatibility before attempting the upgrade.