Class L fuses are fast-acting blade fuses, and the Mersen A15QS300-4 is a 300 A example rated 150 VAC and 150 VDC. The listing also shows Mersen semiconductor blade fuses, including the A70P100-4 at 100 A and the A50P800-4 at 800 A. The Class L examples, the A15QS300-4 and the A15QS600-4, are both described at 100 kA at AC and 50 kA at DC, while the semiconductor A70P100-4 is described at 100 kA at AC and DC. Amperage, voltage and kA ratings vary by model, so each fuse has to be matched on its own spec line. Each Mersen model here lists its amperage and voltage directly, which gives contractors a clear starting point for any comparison. Getting the ratings correct matters because a fuse protects the circuit it is installed in.
Subcategories
Buying Guide
Start with amperage. The Mersen examples here range from 100 A to 800 A, and the required amperage should come from the circuit design or the fuse being replaced.
Next, check voltage. The Class L examples list 150 VAC/150 VDC, the A70P100-4 and A70P175-4 list 700 VAC/650 VDC, and the A50P800-4 lists 500 VAC/450 VDC. Voltage ratings differ by model, so the system voltage should be compared with each fuse before a part is chosen. Matching the fuse to the original part number is a practical check on a replacement job.
Then look at the kA rating. The Class L examples are described at 100 kA at AC and 50 kA at DC, while the A50P800-4 is described at 100 kA at AC and 79 kA at DC. When shopping Class L fuses, compare the DC rating separately, since it can differ from the AC rating on the same fuse.
Finally, confirm the physical size. Listed lengths run from 3-1/2 inch OAL on the A15QS600-4 to 6-15/32 inch OAL on the A50P800-4, so the mounting space matters. Also note the Class L and semiconductor labels in the product names, since the two types are listed in the same category. Product pages carry the full spec list for each model, and the examples here are a sample rather than the complete assortment.
Frequently Asked Questions
What amperage options do Class L fuses come in?
Class L fuses in this listing include the Mersen A15QS300-4 at 300 A and the A15QS600-4 at 600 A. The category also includes Mersen semiconductor blade fuses from 100 A to 800 A. Each model's amperage is shown on its product page.
What voltage are the Mersen Class L fuses rated for?
The Mersen A15QS300-4 and A15QS600-4 Class L fuses both list 150 VAC/150 VDC. Some semiconductor blade fuses in the category list higher ratings, such as 700 VAC/650 VDC on the A70P100-4.
What kA ratings do the Class L fuses list?
The Mersen A15QS300-4 and A15QS600-4 Class L fuses are described at 100 kA at AC and 50 kA at DC. Class L fuses should be compared on both numbers, since the AC and DC ratings differ.
What is the physical size of the Mersen 600 A Class L fuse?
The Mersen A15QS600-4 Class L fuse is listed at 3-1/2 inch OAL and 1-1/2 inch diameter. Size is worth checking on any Class L fuse because mounting space varies by job.
Are semiconductor fuses listed with the Class L fuses?
Yes, the Class L fuses category lists Mersen semiconductor blade fuses such as the A70P175-4, a 175 A model at 700 VAC/650 VDC. The A50P800-4 is an 800 A semiconductor model at 500 VAC/450 VDC. Each is labeled by type in the product name, so the right one can be picked by label.