Ventilation Fans are the equipment contractors use to move, exhaust, or bring in air for a space, and the category at SupplyHouse covers more than one product type. The sampled listings include a fresh air ventilator, an exhaust fan kit, a door air curtain, a room to room transfer fan, and a dehumidistat control. Specs vary widely. The S&P TD100 exhaust kit lists airflow capacities of 100 and 135 CFM on a 4 inch duct, while the Mars Air LoPro Series 2 air curtain lists 900 CFM at high speed. Brands in the sample include Aprilaire, S&P, Mars Air, Tjernlund, and Field Controls. Each product type serves a different job, from supplying outside air to moving air between rooms. Matching airflow, duct size, voltage, and control method to the application keeps the system correctly sized and straightforward to wire.
Subcategories
Buying Guide
Start by defining the job, because the right product type depends on whether the goal is fresh air supply, exhaust, room to room air movement, or doorway air control. Once the type is set, size to the airflow figure on the listing. The S&P TD100 lists 100 and 135 CFM, the Tjernlund AireShare lists 75 CFM, and the Mars Air LoPro Series 2 36 inch lists 900 CFM at high speed.
Next, match duct size and electrical supply. The TD100 kit uses a 4 inch duct at 120V, while the Aprilaire V42SNX uses 6 inch inlet and outlet connections at 115V. The Mars Air unit runs on 208/230V single phase, so the circuit has to be confirmed before it is ordered. The V42SNX also needs a plug-in, switched outlet and 24-volt wiring.
When selecting Ventilation Fans, confirm what ships in the box. The TD100 kit includes the fan, an intake grille, and an exterior louvered grille, and the V42SNX includes the 8120X digital ventilation control. Control method matters as well. The AireShare hard wired version can run from a wall switch or thermostat, and the Field Controls EDH dehumidistat runs a crawl space fan at a set humidity level on 120 volts.
Finally, check warranty and noise. The V42SNX lists a 5 year warranty, and the Mars Air unit lists 49 decibels.
Frequently Asked Questions
How do I size ventilation fans by CFM?
Size ventilation fans to the airflow the application calls for, then match the listing's CFM. The S&P TD100 exhaust kit lists 100 and 135 CFM, and the Tjernlund AireShare lists 75 CFM with 150 square feet of coverage.
What duct size does the Aprilaire V42SNX fresh air ventilator use?
The Aprilaire V42SNX lists a 6 inch inlet and a 6 inch outlet. It includes a backdraft damper and the 8120X digital ventilation control. Verify the electrical supply, since it runs on 115V and needs a plug-in, switched outlet plus 24-volt wiring.
Does an exhaust fan kit come with grilles?
The S&P TD100 Standard Exhaust Kit (Single Vent) includes one TD100 fan, one PG-100 plastic round intake grille, and one PER-100W louvered exterior grille. It uses a 4 inch duct and runs on 120V. Ventilation fans sold as kits vary, so check each kit's contents.
Can a transfer fan be wired to a thermostat?
The Tjernlund AireShare hard wired version can be activated from a wall switch or thermostat. It lists 75 CFM, 25 watts, and 120V. Confirm wiring requirements on the listing before installing.
What control works for a crawl space fan?
The Field Controls EDH Eliminator De-Humidistat is a 120 volt control that operates a fan at a set humidity level in a crawl space. Among the ventilation fans and controls in this category, it is the humidity based option. Pair it with a compatible fan and confirm voltage first.