Apply to be a TradeMaster!
Filter menu expanded

Filters

1,443 items
Reset

SORT

Product Availability
–

Show In Stock Only (1070)
Reno (3)

Phase
–

1 (556)
3 (113)

Insulation Class
–

A (78)
B (473)
F (73)
H (1)

Horse Power
–

1/120 (1)
1/100 (1)
1/75 (1)
1/70 (2)
1/60 (1)
1/50 (1)
1/40 (3)
1/30 (8)
1/25 (9)
1/20 (17)

Mount
–

C (12)
Cushion Base (41)
Cushion Ring (8)
Extended Studs (125)
Flexible Arms (14)
Lug (13)
N (1)
Plate (1)
Resilient Base (118)
Resilient Ring - Extended Studs (39)

Duty
–

Air Over (287)
Continuous (263)
Continuous Air Over (26)

Enclosure Type
–

Drip Proof (96)
Open (89)
Open Air Over (63)
Open Drip Proof (115)
Open Ventilated Air Over (6)
Semi-Enclosed (89)
TEAO (37)
TEFC (29)
TEFC (1)
TENV (13)

Amperage
–

0.3 (1)
0.5 (1)
0.6 (1)
0.63 (1)
0.64 (1)
0.7 (5)
0.74 (1)
0.75 (3)
0.78 (1)
0.8 (1)

Voltage
–

115V (306)
120v (2)
277v (13)
460v (146)
575v (9)
115 (1)
115/208-230v (15)
115/230V (25)
190V (1)
200-230/460V (12)

RPM
–

500 (1)
700 (1)
715 (1)
750 (4)
800 (3)
825 (30)
840 (1)
850 (15)
900 (2)
920 (1)

Original Equipment Manufacturer
–

Aaon (5)
American Air Filter (1)
Arcoaire (1)
Armstrong (2)
BDP (11)
Bell & Gossett (2)
Carrier (11)
Coleman (2)
Copeland (3)
Evcon (2)

Motor Orientation
–

Any (116)
Horizontal (196)
Vertical Shaft Down (5)
Vertical Shaft Up (18)
Vertical Shaft Up Or Down (2)

Speeds
–

1 (399)
2 (70)
3 (82)
4 (25)
5 (5)

Rotation
–

CCW (9)
CCWLE (103)
CCWPE (45)
CCWSE (4)
CW (11)
CW/CCW (13)
CWLE (22)
CWSE (6)
RCCW (82)
RCW (22)

Poles
–

2 (89)
4 (184)
6 (270)
8 (43)
10 (1)

Overload Protection
–

Automatic (427)
Manual (4)
None (70)
Thermally (125)

Frame
–

143T (2)
145JM (1)
145T (3)
182T (2)
184T (4)
213T (1)
4.4 (8)
42 (17)
42Y (56)
48 (75)

Review Score
–

(58)
(2)
(2)
(1)

Price Range
–

$10 to $15 (3)
$15 to $20 (2)
$20 to $25 (1)
$25 to $30 (3)
$30 to $35 (3)
$35 to $40 (7)
$40 to $45 (3)
$45 to $50 (2)
$50 to $60 (5)
$60 to $70 (4)

Century Motors

Help Face
Need a little help?
1443 items
Grid
List
Compare
Product Image of SK1102 Pool and Spa Motor
SK1102 Pool and Spa Motor
SKU: SK1102
Century
SKU: SK1102
Brand: Century
$362.00 each
In Stock
Get 9 by Tue, Oct 27
In Stock
Get 9 by Tue, Oct 27
Compare
Product Image of SK1152 Pool and Spa Motor
SK1152 Pool and Spa Motor
SKU: SK1152
Century
SKU: SK1152
Brand: Century
$481.26 each
In Stock
Get 3 by Tue, Oct 27
In Stock
Get 3 by Tue, Oct 27
Compare
Product Image of SN1302 Pool and Spa Motor
SN1302 Pool and Spa Motor
SKU: SN1302
Century
SKU: SN1302
Brand: Century
$969.65 each
In Stock
Get 1 by Tue, Oct 27
In Stock
Get 1 by Tue, Oct 27
Resources
FAQs, Manuals & Videos
Articles
More About Century Motors

Century Motors are Regal Rexnord's line of OEM replacement motors for HVAC and refrigeration equipment, covering 42-frame and 48-frame permanent split capacitor designs used across condenser fan and indoor blower applications. Century has supplied motors to the HVAC trade for over a century, and its replacement lineup is built to cross-reference against hundreds of the most common factory motors rather than requiring an exact brand match. A technician replacing a failed condenser fan or blower motor typically needs horsepower, voltage, RPM, and frame size before selecting a Century unit, since PSC motors are matched by electrical and physical specification rather than by the equipment brand alone. Stocking a range of Century frame sizes and horsepower ratings covers the bulk of service calls on multi-brand HVAC fleets.

Subcategories

  • Condenser Fan Motors: Condenser fan motors move air across the outdoor coil on air conditioning and heat pump condensing units, and Century's 48-frame PSC designs are built to cross-reference against the motors used across most major HVAC brands. HeatMaster and HeatMaster Ultra condenser fan motors carry UL and CSA approved Class F insulation, rated for 70 degrees C and 80 degrees C maximum ambient conditions respectively, which matters for units mounted in direct sun or tight enclosures. A technician confirms horsepower, voltage, RPM, and rotation direction before ordering a replacement condenser fan motor. Getting the frame size and shaft length right avoids a return trip for a second part.
  • Indoor Blower Motors: Indoor blower motors circulate air through the furnace or air handler and back into the ductwork, and Century's MasterFit Pro line covers this application in a 48-frame PSC design with multiple mounting options. A multi-rating capacitor built into the MasterFit Pro motor lets one part cover several capacitance requirements instead of stocking a separate capacitor for each replacement. Confirming horsepower and speed tap count against the OEM motor keeps airflow and static pressure within the original equipment's design range. Blower motor replacements are among the more common HVAC service calls, since these motors run far more duty cycles than condenser fan motors.
  • OEM Cross-Reference Replacement Motors: Century motors are designed to replace hundreds of the most popular factory-installed motors across HVAC brands, rather than requiring a match to a single manufacturer's part number. This cross-reference approach lets a contractor stock Century frame sizes and horsepower ratings instead of carrying brand-specific inventory for every piece of equipment on a service route. Matching by electrical rating, frame size, and mounting style, rather than by brand name, is what makes a Century motor a valid replacement for a failed OEM unit. This approach also shortens lead time on repairs where the original manufacturer's part is backordered.

Buying Guide

Century Motors selection starts with identifying whether the failed part is a condenser fan motor or an indoor blower motor, since the two applications use different mounting styles and airflow requirements even when frame size overlaps. Once application is confirmed, horsepower, voltage, and RPM need to match the original motor's nameplate data, since Century motors are matched by electrical specification rather than brand name. Frame size, either 42-frame or 48-frame, narrows the physical mounting options further, and shaft length and diameter should be checked against the original motor before ordering. For condenser fan replacements, ambient temperature at the installation site matters: HeatMaster motors are rated for 70 degrees C maximum ambient, while HeatMaster Ultra motors extend that rating to 80 degrees C for units installed in hotter enclosures or direct sun exposure. For blower motor replacements, MasterFit Pro's multi-rating capacitor simplifies capacitor selection, since one part can cover a range of capacitance values instead of requiring an exact match. Rotation direction, whether the motor turns clockwise or counterclockwise when viewed from the shaft end, is a detail that gets missed on Century Motors orders and causes an otherwise correct motor to run the fan or blower backward. Checking nameplate horsepower, voltage, RPM, frame size, shaft dimensions, and rotation direction against the failed motor before ordering covers the specifications that determine whether a Century replacement will fit and perform correctly.

Frequently Asked Questions

Are Century motors interchangeable with motors from other HVAC equipment brands?

Yes. Century motors are designed to cross-reference against hundreds of the most popular factory motors by matching horsepower, voltage, RPM, frame size, and rotation direction rather than by equipment brand. Confirming those specifications against the original motor's nameplate is what determines fit, not the brand of equipment it's installed in.

What's the difference between HeatMaster and HeatMaster Ultra condenser fan motors?

Both are 48-frame PSC condenser fan motors with UL and CSA approved Class F insulation, but HeatMaster is rated for 70 degrees C maximum ambient temperature while HeatMaster Ultra extends that rating to 80 degrees C. HeatMaster Ultra suits condensing units installed in direct sun or tight enclosures where ambient heat runs higher.

What does the multi-rating capacitor on a MasterFit Pro motor do?

It lets a single motor cover several capacitance requirements instead of needing a separately matched run capacitor for each application. This reduces the number of parts a contractor needs to stock for blower motor replacements.

How do I confirm the correct frame size for a Century replacement motor?

Century motors are offered in 42-frame and 48-frame sizes, and the correct one is determined by the physical dimensions and mounting style of the original motor, not just its horsepower. Checking the failed motor's frame designation and shaft length before ordering avoids a mismatch.

Why does rotation direction matter when ordering a Century motor?

A condenser fan or blower motor that turns the wrong direction won't move air correctly even if every other specification matches. Rotation direction is typically listed on the original motor's nameplate and should be confirmed before placing a Century Motors order.

Didn't find what you're looking for? 
Let us know
.