Shop Resideo Sale
Main product image of Universal Silicon Carbide Integrated Ignition Control
Magnifying glass
Hover image to zoom

Universal Silicon Carbide Integrated Ignition Control

SKU:
50A55-843
Rating:
(156)
Q&A:
(20)
Universal Silicon Carbide Integrated Ignition Control
Magnifying glass
Hover image to zoom
$136.95 each
In Stock
In Stock
Get 399 Tue, Nov 17
Order by today, receive Tuesday
Free Shipping This item ships free
Easy Returns No restocking fee for 90 days

Description

–

Please note: This SKU is a direct replacement for 50A50-241

The 50A55-843 Universal Silicon Carbide Integrated Ignition module employs a microprocessor which continually monitors, analyzes and controls the proper operation of the gas burner, inducer and fan. The Universal Module includes an extensive cross-reference, additional jumper wires, an additional wiring harness and a jumper for Trane applications. The module also has terminals for powering a humidifier and electronic air cleaner.


Specifications

  • Input Voltage: 25 VAC 50/60 Hz
  • Maximum Input Current: 25 VAC . 0.45 amp
  • Valve Relay: 1.5 amp @ 25 VAC 50/60 Hz 0.6 pf
  • Ignitor Relay: 6.0 amp @ 120 VAC 50/60 Hz (resistive)
  • Inducer Relay: 2.2 FLA - 3.5 LRA @ 120 VAC
  • Circulator Relay: 14.5 FLA - 25.0 LRA @ 120 VAC
  • Operating Temperature Range: -40 to +175°F (-40 to +79°C)
  • Humidity Range: 5% to 93% relative humidity

Features

  • Includes flash code diagnostics
  • Fused to protect low voltage system transformers
  • Includes mounting hole template
  • Input Voltage - 25 VAC 50/60 Hz
  • Adjustable blower relay


Help Face

Questions?

Speak with a real person who will go out of the way to help!
Call or text 888-757-4774
Monday – Thursday
8am–7:45pm
Friday
9am–7:45pm
Saturday – Sunday
9am–5:45pm

Response by Tue

Compare Similar Products

Brand
CURRENT ITEM
Product Image of Universal Silicon Carbide Integrated Ignition Control
Universal Silicon Carbide Integrated Ignition Control
SKU: 50A55-843
(156)

You May Also Need

Single-Stage/HSI Integrated Furnace Control Kit
SKU: 21D83M-843
White Rodgers

Product Reviews

4.81 out of 156 reviews
98% would recommend this product
4.81
out of 156 Reviews
98% would recommend this product
WRITE A REVIEW
5 star
91%
4 star
5%
3 star
1%
2 star
1%
1 star
3%
WRITE A REVIEW
Customer Images

Most Liked Positive Review

Work great!

White Roger recommends this unit to replace it's older 50A50 line of controller board and it works as advertised. You may have to jumper the OD1 and OD2 pins on the 12-pin connector if your furnace don't support this feature. Look to see if there are wires on the OD1 and OD2 pin of your existing 12-pin connector. The pin layout is on the controller board. Use the black jumper wire that come with the replacement unit to jumper these two pins on your existing 12-pin connector if your furnace doesn't support this safety feature. What I really like about this replacement unit is the on-board diagnostic function indicated by the flashing LED and the product manual that came with the package. After I installed the unit and power on, the diagnostic LED flashes 5 times so I looked up in the manual to find the OD1 & OD2 issue. Since my old furnace doesn't have this feature, I jumper the two pins and power the unit on again. This time the diagnostic LED flashes 4 time indicating the (temperature) limit switch is open. I look up on the internet to find out what the limit switch looks like, locate the switch and ohm it out (with the power OFF). Apparently my limit switch is stuck open and need to be replaced. A temporary fix is to unstick the switch by flicking my finger against it several times. This will work until it stuck open again so REPLACE this part. When I put everything back together, the furnace came on and the family have heat once again. Apparently my old controller board still work b'cuz my problem was the limit switch stuck open. However, the diagnostic function on the old controller board did not help me to figure out the problem so I opted to leave the new one in my furnace. This newer unit will help me to diagnostic any problems that may occurred in the future.
VS

Most Liked Negative Review

Not a replacement for 50A50-405

I purchased the 50A55-843 as a replacement for the 50A50-405 on a Cumberland Model FCAC100A50A1 that was used for the second stage heat in a dual-fuel heat pump system. When installed in furnace the blower would run all the time and the burners would not come on when the system was calling for emergancy heat. This was the case regardless of where the thermostat was set. Found a new 50A50-405 locally, installed it and everything went back to working.
Showing 1-10 of 156 reviews

Fixed all my problems

This controller was perfect for replacing my older controller. Came with extension wires to extend current wires to new location. Fast delivery
Mike
Ma
11 days ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

50A50-474: 5 LED Flashes "Flame sensed with gas valve off"

Problem Solved: model 50A50-474 Recurring 5-Flash Error Code (Flame sensed with gas valve off) and blower running continuously on lockout after reaching set point during a longer heating cycle. My Trane XE90 furnace was repeatedly going into a safety lockout displaying this error code after heating stopped and the gas valve closed, after which the indoor blower fan would run continuously for approximately twenty to thirty minutes before timing out and shutting off on its own. Notably, the fault occurred only after longer heating cycles and did not trigger during shorter test runs while troubleshooting. The root cause was an internal failure on the old control board, model 50A50-474, specifically within its flame sensing and rectification logic circuit, likely due to thermal expansion of the board causing microfractured solder joints to separate and incorrectly detect ghost flame signals while the gas valve was off following a long heating cycle. Replacing the control board resolved the issue immediately. While it used the same spade size and Molex connectors, the wire locations on the new board were different, and I used the supplied jumper wire for the 12-pin Molex connector required for Trane systems. Because of the new mounting position, I also needed to use wire extensions, though that was strictly a matter of physical placement rather than function. As a routine maintenance precaution, I installed the new flame sensor even though it wasn't strictly needed. Moving all the wires over to the new board worked immediately upon power-up. No error codes for flame detected after gas valve shut off, and the furnace now ignites smoothly, maintains normal heating cycles, and shuts down safely with zero fault codes. If your Trane furnace 50A50-474 board gives a 5-flash code after a long run, do not overlook the control board. A fresh board fixed the issue completely and restored normal operation.
Badley
San Jose, CA
23 days ago
Was this review helpful to you?

I would buy this product again !

Worked like it should and it shipped fast!
George
Corning, Ohio
24 days ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

Excellent customer service

I've ordered lots of parts through supply house normally w no issues. This board stop working after about 6 months and I contacted customer service. They expedited my replacement board. It was at my door in under 24 hrs from it being shipped.. excellent customer service
Phil
Louisiana
6 months ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

Great return policy.

Ordered two parts. First one was the wrong part. They took it back and sent me the correct part.
TC
Madison GA
7 months ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

Perfect replacement

My outdated control board failed on the fan control relay due to burned out relay switch. This was the listed replacement option. I was a little concerned because the board was not an exact match but all indications showed that this was the upgraded replacement so I took a chance. All the connections were the same but some were in different locations on the board. Very easy upgrade and swap.
Happy
Sr Louis
7 months ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

I recommend thos part

Perfect solution to a customers furnace issue.
Mick
SC
8 months ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

I will recommend supply house to others

Repaired my sister in laws furnace. Customer service was outstanding
ray
SC
9 months ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

Last two DOA

Last two ordered were DOA in the 24v side. 24v not present at R terminal when power is applied.
Double A
Missouri
10 months ago
Was this review helpful to you?

I would by this control board again

Fast shipping furnace was back working in 2 day
Paul
Twin Falls
11 months ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

Product Q&A

20 Questions
20 Questions
ASK A QUESTION

Q: Will this replace 50A55-438 ? (American Standard furnace)

Asked by Louie 14 years ago

Add your answer

* Required Field
Verified Author and ReplyVerified Reply- PexSupply Staff

Yes, it will.

Was this review helpful to you?

Q: does this replace the 50A50-112 General 90 inter City Products? Does it come with all wiring needed for complete operation?

Asked by Craig 15 years ago

Add your answer

* Required Field
Verified Author and ReplyVerified Reply- PexSupply Staff

Yes, 50A55-843 is the replacement for the obsolete 50A50-112. This part comes as pictured, but with six different wires.

Was this review helpful to you?

Q: Will this replace 50A50-241?

Asked by 15 years ago

Add your answer

* Required Field
Verified Author and ReplyVerified Reply- PexSupply Staff

Yes, 50A55-843 is the manufacturer's recommended replacement for the obsolete 50A50-241.

Was this review helpful to you?

Q: Does the 50A55-843 replace a 50A50-473 (American Standard Furnace)? thanks

Asked by Nathji 15 years ago

Add your answer

* Required Field
Verified Author and ReplyVerified Reply- PexSupply Staff

50A55-843 is the manufacturer's recommended replacement for 50A50-473.

Was this review helpful to you?

Q: IS THE 50A55-843 a replacement for 50A50-206, also is it for heating and airconditioning.

Asked by 15 years ago

Add your answer

* Required Field
Verified Author and ReplyVerified Reply- PexSupply Staff

Yes, part 50A55-843 is the manufacturer's recommended replacement for 50A50-206.

Was this review helpful to you?

Q: WILL THIS REPLACE 50A55-288-05 THANKS

Asked by TOPCAT 15 years ago

Add your answer

* Required Field
Verified Author and ReplyVerified Reply- PexSupply Staff

50A55-843 replaces 50A55-288. We cannot reference 50A55-288-05.

Was this review helpful to you?
- welder.will

it was the exact replacement for my WR 50A55-288. Dont know about the additional 05 on your model but i suspect this is your replacement model

Was this review helpful to you?

Q: Will this be a direct replacement for a 50A50-110

Asked by Frank 15 years ago

Add your answer

* Required Field
Verified Author and ReplyVerified Reply- PexSupply Staff

Yes, 50A55-843 is the manufacturer's recommended replacement for 50A50-110.

Was this review helpful to you?

Q: Can 50a55-843 replace 50A50-112 or 50A50-142? It is for Air conditioner and heating.

Asked by Richard 15 years ago

Add your answer

* Required Field
Verified Author and ReplyVerified Reply- PexSupply Staff

Yes, the manufacturer lists 50A55-843 as the replacement for both those items.

Was this review helpful to you?

Q: HOW DO YOU WIRE A 50A55-843 TO REPLACE A 50A55-571? IT'S A TRANE UNIT.

Asked by COIL 16 years ago

Add your answer

* Required Field
Verified Author and ReplyVerified Reply- PexSupply Staff

To wire the new unit to replace the old one, you need to match up the terminals.

Was this review helpful to you?

Q: will this replace the 50A50-298 board?

Asked by 16 years ago

Add your answer

* Required Field
Verified Author and ReplyVerified Reply- PexSupply Staff

The 50A55-843 Universal Silicon Carbide Integrated Ignition module is a direct replacement for the 50A50-298.

Was this review helpful to you?
Free Shipping
On orders over $99
We offer flexible shipping and scheduling options, up-to-date delivery estimates, and free ground shipping on any order over $99 to make sure your order gets to you on-time, for less.
Shipping Policy
Easy Returns
Returning items is as simple as 1-2-3
Ordered the wrong product? Item damaged in transit? Our 3-step process makes returning products easy – even up to a year after purchase – with no restocking fees on returns made within 90 days.
Return Policy