Apply to be a TradeMaster!
Filter menu expanded

Filters

224 items
Reset

SORT

Product Availability
–

Show In Stock Only (85)

Brand
–

Eaton (5)
Leviton (49)
Siemens (61)
Square D (109)

Amperage
–

30 (2)
40 (1)
50 (2)
60 (4)
70 (4)
100 (37)
125 (45)
150 (18)
200 (56)
225 (25)

Number Of Circuits
–

2 (5)
3 (2)
8 (12)
12 (10)
16 (19)
18 (2)
20 (16)
24 (16)
27 (1)
30 (20)

Spaces
–

2 (13)
3 (2)
4 (3)
6 (5)
8 (28)
12 (14)
16 (5)
18 (2)
20 (24)
24 (12)

Installation Type
–

Indoor Only (116)
Indoor/Outdoor (1)
Outdoor Only (76)

Mount
–

Flush (7)
Lug (2)
Outdoor Mount (1)
Plug-On Neutral (11)
Surface (34)

Voltage
–

120v (113)
240v (124)
120/240V (43)
208V (1)
600V (3)

Current (amps)
–

10 kA (38)
22 kA (65)
25 kA (6)
65 kA (29)

Review Score
–

(12)
(3)
(1)
(1)

Price Range
–

$5 to $10 (2)
$10 to $15 (3)
$15 to $20 (3)
$20 to $25 (1)
$25 to $30 (2)
$35 to $40 (3)
$40 to $45 (1)
$45 to $50 (1)
$50 to $60 (6)
$60 to $70 (6)

Electrical Panel Boxes

Help Face
Need a little help?
224 items
Grid
List
Compare
Product Image of 8 Circuit, 8 Space Overhead Ringless Meter Main Combo Breaker w/ Lever Bypass (200A)
8 Circuit, 8 Space Overhead Ringless Meter Main Combo Breaker w/ Lever Bypass (200A)
SKU: LS820-BLD
Leviton
SKU: LS820-BLD
Brand: Leviton
$626.42 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of 42 Circuit, 42 Space Outdoor Load Center Main Breaker, 120/240V (225A)
$345.85 each
In Stock
Get 2 by Mon, Nov 23
In Stock
Get 2 by Mon, Nov 23
Compare
Product Image of Homeline 24 Space, 48 Circuit Convertible Load Center Main Breaker, Plug-on Neutral, 1 Phase, 120/240V (100A)
$529.70 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of Homeline 30 Space, 60 Circuit Convertible Load Center Main Breaker, Plug-on Neutral, 1 Phase, 120/240V (150A)
$814.73 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of Outdoor Flush Mount Solar Ready Meter Load Center Combination, Single Phase, 24 Spaces/42 Circuits (120/240V, 200A)
$526.53 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of Indoor Load Center, Single Phase, 8 Spaces/16 Circuits (120/240V, 200A)
$431.31 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of Homeline 20 Space, 40 Circuit Convertible Load Center Main Breaker, Plug-on Neutral, 1 Phase, 120/240V (100A)
$423.46 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of Homeline 30 Space, 60 Circuit Convertible Load Center w/ Main Lugs, Plug-on Neutral, 1 Phase, 120/240V (125A)
$384.97 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of Homeline 40 Space, 80 Circuit Convertible Load Center w/ Main Lugs, Plug-on Neutral, 1 Phase, 120/240V (225A)
$639.77 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of 12 Circuit, 12 Space Outdoor Ring-Type Meter Main Combo Break, Solar Ready (125A)
$469.19 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of PN Series Indoor Load Center Circuit Main Breaker with Copper Bus, Single Phase, 12 Spaces/24 Circuits 120/240V (125A)
$110.90 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of PN Series Indoor Main Lug Plug-On Neutral Load Center w/ Copper Bus, Single-Phase, 20 Spaces/40 Circuits (120/240V, 150A)
$199.40 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of Indoor Load Center Circuit Breaker Enclosure, Single Phase, 30 Spaces/30 Circuits 120/240V (150A) with Copper Bus
$287.57 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of QO 16 Space, 24 Circuit Convertible Load Center Main Breaker, Plug-on Neutral, 1 Phase (100A)
$388.14 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of QO 42 Space, 52 Circuit Indoor Convertible Load Center Main Breaker, Plug-on Neutral w/ Qwik-Grip, 1 Phase (200A)
$1,145.21 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of QO 20 Space, 24 Circuit Convertible Load Center w/ Main Lugs, Plug-On Neutral w/ Ground Bar, 1 Phase (125A)
$297.07 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of QO 30 Space, 30 Circuit Indoor Convertible Load Center Main Breaker, 1 Phase, 120/240V (200A)
$956.32 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of QO 2 Pole Outdoor Load Center Circuit Breaker Enclosure, 2 Space, 120/240V (100A)
$56.75 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of QO 2 Space, 4 Circuit Indoor Load Center w/ Main Lugs w/ Flush Cover, 1 Phase, 120/240V (70A)
$63.27 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of QO 27 Space, 27 Circuit Load Center Main Breaker, 3 Phase, 120/240V (100A)
$577.37 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of QO 24 Space, 34 Circuit Convertible Load Center Main Breaker, Plug-On Neutral, 1 Phase (125A)
$290.99 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of QO 30 Space, 30 Circuit Indoor Convertible Load Center w/ Main Lugs, PoN w/ Ground Bar, 1 Phase (200A)
$591.18 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of QO 30 Circuit Outdoor Main Breaker Plug-On Neutral Load Center, 30 Space, 120/240V (200A)
$525.27 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of QO 54 Space, 64 Circuit Indoor Convertible Load Center w/ Main Lugs, PoN w/ Ground Bar, 1 Phase (225A)
$1,144.30 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of QO 20 Space, 20 Circuit Indoor Load Center w/ Main Lugs w/ Ground Bar, 3 Phase, 240V (125A)
$424.56 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of QO 8 Space, 16 Circuit Indoor Load Center w/ Main Lugs & Flush Cover, 1 Phase, 120/240V (100A)
$120.11 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of QO 24 Space, 34 Indoor Circuit Convertible Load Center Main Breaker, Plug-on Neutral, 1 Phase (125A)
$822.46 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of QO 42 Circuit Indoor Main Breaker Load Center, 42 Space, 208Y/120V (225A)
$1,080.65 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of Indoor Load Center Circuit Breaker Enclosure, Single Phase, 30 Spaces/30 Circuits 120/240V (125A) with Copper Bus
$226.71 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of PN Series Indoor Load Center Main Breaker, 1-Phase, 30 Spaces/48 Circuits 120/240V (125A)
$175.56 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Compare
Product Image of PN Series Indoor Load Center Circuit Main Breaker with Copper Bus, Single Phase, 12 Spaces/24 Circuits 120/240V (100A)
$159.80 each
In Stock
Get 1 by Mon, Nov 23
In Stock
Get 1 by Mon, Nov 23
Compare
Product Image of PN Series Outdoor Main Lug Plug-on Neutral Load Center, w/ Copper Bus, Single-Phase, 8 Spaces/16 Circuits (120/240V, 200A)
$200.06 each
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Backorder
Get it by Tue, Dec 22 - Mon, Jan 25
Resources
FAQs, Manuals & Videos
Articles
More About Electrical Panel Boxes

Electrical panel boxes house the circuit breakers or fuses that distribute power throughout a building, serving as the central point where incoming utility power splits into the individual circuits feeding outlets, lighting, and equipment. Each box is rated for a specific number of circuit spaces and a maximum amperage, so matching the box to the building's electrical load and the number of circuits needed is central to a code compliant installation. Electricians install new panel boxes when replacing outdated equipment, expanding a building's electrical capacity, or setting up service for new construction or renovation. Because a panel box sits at the center of a building's entire electrical distribution, choosing the correct amperage rating, circuit count, and enclosure type for the installation environment affects both the safety and the future expandability of the system it serves.

Subcategories

  • Main Breaker Panels: Main breaker panels include a built in main disconnect breaker that can shut off power to the entire panel from a single switch, which many jurisdictions require for a service entrance panel. Electricians typically install these as the primary panel where utility power first enters a building's electrical system. Sizing the main breaker to match the service entrance conductors and the utility's rated capacity is necessary for a code compliant installation. Because the main disconnect lives inside the panel itself, no separate disconnect switch is needed elsewhere in the system.
  • Main Lug Panels: Main lug panels connect incoming power directly to the bus bar without a built in main disconnect breaker, relying on an upstream breaker or disconnect elsewhere in the system to shut off power. These see use as sub panels fed from a main breaker panel, or in service configurations where the disconnect is required to be located separately from the panel. Confirming local code allows a main lug configuration for the specific application, since disconnect location requirements vary, is worth checking before installation. Matching the lug's wire gauge rating to the feeder conductors keeps the connection within its rated capacity.
  • Sub Panels: Sub panels distribute power to a specific area of a building, such as a detached garage, finished basement, or an addition, and are fed from a main panel elsewhere in the electrical system. Electricians add these when an area needs more circuits than the existing panel has room for, or when running individual circuits back to the main panel isn't practical because of distance. Sizing the feeder breaker at the main panel and the sub panel's own rating to match the actual load served keeps the installation within code. A sub panel located outdoors or in a detached structure typically needs a rated enclosure suited to that environment.
  • Panel Box Accessories & Covers: Panel accessories cover the smaller components that complete a panel installation, including blank filler plates for unused breaker spaces, circuit directory labels, and replacement covers or doors for existing panels. Electricians replace a damaged or missing cover promptly, since an open panel front is both a safety hazard and typically a code violation. Filler plates for unused spaces keep the panel enclosure properly rated against dust and incidental contact. Keeping a panel's circuit directory current, rather than relying on outdated labels, saves time for the next electrician working on the same panel.
  • Buying Guide

    Choosing the right electrical panel box starts with calculating the building's actual electrical load, including existing circuits and any anticipated future additions, since undersizing a panel now often means a costly upgrade later when capacity runs out. A main breaker panel is the right choice where a built in disconnect is required or preferred at the service entrance, while a main lug panel suits sub panel applications or configurations where the disconnect is located elsewhere in the system, provided local code permits that arrangement. Sub panels extending power to a detached structure, addition, or area with additional circuit needs should be sized to the load they'll actually serve, with the feeder breaker at the main panel matched to the sub panel's rating. Enclosure type matters as much as electrical rating: an indoor panel in a dry, conditioned space has different requirements than one installed outdoors or in a damp basement, and choosing the correct enclosure rating for the installation environment is a code requirement, not just a durability preference. Circuit count deserves attention beyond the immediate need, since a panel with a few spare spaces costs little more than one filled to capacity and avoids a full panel swap the next time a circuit needs to be added. Confirming compatibility between the panel and the breakers already on hand, or planned for use, rounds out the specification before ordering.

    Frequently Asked Questions

    What's the difference between a main breaker panel and a main lug panel?

    A main breaker panel includes a built in disconnect breaker that shuts off the entire panel, while a main lug panel connects directly to the bus bar and relies on a disconnect located elsewhere in the system, typically at an upstream main panel.

    How is the correct amperage rating determined for a new panel?

    Calculating the building's actual electrical load, including existing circuits and any anticipated future additions, determines the appropriate amperage rating, and sizing with some spare capacity avoids a costly full panel upgrade later.

    When is a sub panel needed instead of running new circuits to the main panel?

    A sub panel makes sense when an area needs more circuits than the main panel has room for, or when the distance to the main panel makes running individual circuits impractical.

    Does the installation environment affect which panel enclosure is needed?

    Yes. An indoor panel in a dry, conditioned space has different enclosure requirements than one installed outdoors or in a damp basement, and matching enclosure rating to the environment is a code requirement.

    Why replace a damaged panel cover promptly?

    An open or damaged panel front leaves live components exposed, which is both a safety hazard and typically a code violation, so replacing it promptly is standard practice.

Didn't find what you're looking for? 
Let us know
.