Robertshaw 710 Series Low Profile Gas Valves are compact combination gas valves built for equipment with limited cabinet space, combining a manual gas cock, automatic pilot safety valve, and pilot filter into a single low-profile body. The series covers multiple control types, including 24 volt, millivolt, and hydraulic snap-acting models, so the correct valve can be matched to the furnace, heater, or appliance's existing control system. Connection sizes include 1/2 inch by 1/2 inch and 3/8 inch by 3/8 inch, with several models rated for 70,000 BTU on natural gas. Every valve in the series mounts in any position except upside down and features a three-position outlet for flexible pilot tubing and burner connections. Because HVAC and appliance techs often work in tight equipment bays with little room for a full-size gas valve, the 710 Series' compact footprint makes it a common replacement choice on RVs, wall furnaces, and other space-constrained gas appliances.
Subcategories
Buying Guide
Matching a replacement valve starts with the control type already wired into the appliance, since 24 volt, millivolt, and hydraulic snap-acting models aren't interchangeable without also changing the appliance's control wiring or thermostat setup. Checking the old valve's model number and control markings before ordering avoids installing a valve that physically fits the cabinet but won't connect to the existing wiring or pilot system. Robertshaw 710 Series Low Profile Gas Valves are built with three-position outlets and component-replaceable parts, so a technician can often service the pilot filter, regulator, or adjusting key individually rather than replacing the entire valve body. Connection size is the next detail to confirm, since 1/2 inch by 1/2 inch and 3/8 inch by 3/8 inch models aren't interchangeable without additional fittings at the gas line. Fuel type matters as well, since natural gas and LP models use different pressure regulators, and a valve set up for natural gas will not deliver correct pressure on LP without a regulator swap. Confirming the BTU rating against the appliance's burner requirements prevents installing an undersized valve that restricts gas flow to the burner. Because these valves see service on space-constrained equipment such as RVs and wall furnaces, checking the physical cabinet clearance in addition to the electrical and gas specs avoids a valve that fits electrically but not physically. Techs who keep a small stock across the common control types and connection sizes can resolve most low-profile valve failures on the first visit.
Frequently Asked Questions
What's the difference between the 24 volt and millivolt Robertshaw 710 valves?
24 volt models rely on line voltage from the appliance's control circuit and thermostat to open the gas valve, matching standard furnace wiring. Millivolt models generate their own operating power from the pilot flame through a thermopile, so no external electrical connection is required to run the valve. Choosing between the two depends entirely on how the appliance's existing control system is wired.
What connection sizes are available on the Robertshaw 710 Series?
The 710 Series includes 1/2 inch by 1/2 inch and 3/8 inch by 3/8 inch connection models, covering a range of appliance gas line sizes. The 710-108 is one example built with a 3/8 inch connection and a right-hand outlet configuration. Matching the connection size to the existing gas line avoids needing an additional reducing fitting during installation.
Can a Robertshaw 710 Series valve be converted from natural gas to LP?
Robertshaw 710 Series valves can generally be converted between natural gas and LP by swapping the pressure regulator rather than replacing the entire valve body. Natural gas and LP require different regulator settings to deliver correct pressure to the burner. Confirming the correct regulator part number for the target fuel type before conversion prevents a pressure mismatch.
What BTU capacity do Robertshaw 710 Series valves support?
Several models in the 710 Series, including the 710-402 and 710-205, are rated for 70,000 BTU on natural gas. Capacity varies by specific model and connection size, so checking the valve's rating against the appliance's burner requirements before installation matters. An undersized valve restricts gas flow and can prevent the burner from reaching its rated output.
In what orientation can a Robertshaw 710 Series valve be mounted?
Robertshaw 710 Series valves can be mounted in any position except upside down, giving some flexibility for tight equipment cabinet layouts. Every model in the series includes a three-position outlet, allowing pilot and burner tubing to be routed in the configuration that best fits the installation. Avoiding an upside-down mount is the one orientation restriction that applies across every valve type in the series.