This is the direct replacement for Slant/Fin 411-873-000 and 411-872-000

Honeywell S8610U3009 Universal Intermittent Pilot Control Module (One or Two Rods) has continuous retry trial time, configurable lockout timing of 15 or 90 seconds and configurable prepurge of 30 seconds or no prepurge.

Field service replacement for most Honeywell, Robertshaw, Johnson, and UTEC (HSC) Intermittent Pilot Ignition Modules. Honeywell S8610U3009 provides electronic control of most intermittent pilot ignition systems used on gas-fired furnaces, boilers, and other heating appliances.

Features:
  • Provides ignition sequence, flame monitoring and safety shutoff for intermittent pilot central furnaces and heating appliances
  • Provides 100 percent pilot gas shutoff if pilot fails to light; after 6-minute delay, trial for ignition is repeated. Ignition trial/delay sequence is repeated until the appliance lights or call for heat is removed
  • For use with Natural or LP gas
  • For use in single rod or dual rod/remote sense applications. Includes relay contacts for use with any intermittent pilot gas control string with maximum 1.0A pilot or 2.0A main valve rating; Honeywell VR8204, VR8304 or VR8345M combination gas control recommended
  • Functional equivalent of S86, S8600, S8610 and S90 modules
  • Includes spark cable adapters to allow field replacement of both Honeywell and competitive controls without replacing existing spark cable

Technical Specifications:
  • Ignition System Type: Intermittent Pilot
  • Ignition Sequence: Continous retry, after trial for ignition, pilot gas shuts off for 5 minutes, then another trial for pilot ignition takes place
  • Typical Gas Control: VR8204, VR8304
  • Type of Gas: Natural or LP
  • Flame Sense: Single Rod or Two Rods
  • Ignition Source: Internal high voltage spark generator
  • PrePurge: Configurable to 30 seconds or no prepurge
  • Ignition Trials To Lockout: continuous retry
  • Lockout Timing: Configurable to 15 seconds or 90 seconds
  • Ignition Trial Time (sec): continuous retry
  • Maximum Valve Load @ 24 Vac (Amps): 1A Pilot, 2A Main @ 165F; 1A Pilot, 1A Main @ 175F
  • Typical Ignition Hardware: Q345, Q3451, Q3452
  • Dimensions: 3-15/16" high x 5-7/16" wide x 2-5/8" deep
  • Electrical Ratings: 24 Vac
  • Frequency: 60 Hz
  • Frequency: 50 Hz
  • Maximum Ambient Temperature: -40F to +165F
  • Approvals, Canadian Standards Association: Design Certified
  • Includes: Damper connection with automatic vent damper plug
  • Tradeline Value: Super Tradeline
  • Between Trial Time (sec): 5 minute delay after failed trial for ignition
  • Flame Failure Response Time (sec): 2 seconds maximum

Specs

Ignition Type:

Intermittent Pilot

Contact

Help Face
CALL US
Question? Call or text 888-757-4774
+
Help Face

Questions?

Speak with a real person who will go out of the way to help!
Call or text 888-757-4774
MondayThursday
8am7:45pm
Friday
9am7:45pm
SaturdaySunday
9am5:45pm

Response by Tue

Compare Similar Products

Brand
CURRENT ITEM
Product Image of Intermittent Pilot Control, S8610U3009
Intermittent Pilot Control, S8610U3009
SKU: S8610U3009
(119)

You May Also Need

Universal Intermittent Pilot Burner for NG/LP w/ Target Style Hood, Q345U1005
SKU: Q345U1005
Resideo

Product Reviews

4.71 out of 119 reviews
96% would recommend this product
4.71
out of 119 Reviews
96% would recommend this product
WRITE A REVIEW
5 star
82%
4 star
13%
3 star
3%
2 star
1%
1 star
2%
WRITE A REVIEW
Customer Images

Most Liked Positive Review

Perfect replacement

I replaced an old UT Electronics model 1003-513 controller. I did not see this in the cross reference as a replacement but it works great. I set the pre-purge to 30 sec as required for my Weil McLain CGI and 15 sec trial for ignition. If you follow the instructions provided by Honeywell with the unit you will not have any problems. It clearly states how you connect to TH-W with the switched 24v. The only time you would use the 24v connection is if you are using an electronic damper. If no damper, do not use the 24v connection. Do not jumper the 24v to TH-W as I have read in other reviews.
VS

Most Liked Negative Review

Not a drop-in and watch it start item.

Product works good once I was able to get it functioning. Its was designed to fit anything,but, I had to build a new bracket to get this item to fit my unit. Directions were poorly written. They were written to remind someone how it should go in not for how to my application.
Showing 1-10 of 119 reviews

the product is ok but the instructions are atrocious

i used it on my boiler and it works but i had to figure out how to make it work because the instructions were so terrible that they didn't make any sense at all
Eddie
Connecticut
5 months ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

Exactly what I need!

Found myself without heating at 5F, 4am ... wasn't fun at all. Was so thankful found the pilot on inventory and got it after 48hrs. On top of this price was by far best compared with other sellers!
Toni
Radford, VA
7 months ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

Like this company

Very helpful
Lindenwood
Hamilton OH.
8 months ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

Fast shipping

Fast shipping
Blue
Ny
10 months ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

Performed like expected

Performed like expected
Jersey guy
New Jersey
1 years ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

I would purchase again if needed

Great replacement for my bad Honeywell pilot controller
JT
Gloversville ny
2 years ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

Nice upgrade from Robertshaw

I decided to give this ignition controller a try after the Robertshaw 780-845 I installed in my water heater last year died almost a year to the day. I do love the extra diagnostic feedback this unit provides especially the amount of micro amps that the flame sensor ground wire is actively sensing. One word of caution, all the spade terminals on this unit are 1/4". The PV solenoid wire on my water heater was 3/16" (with the rest being 1/4") so I need to buy a 3/16" male to 1/4" female adapter to make this work without modification for that singular connection (you could also chop off the connector and recrimp with a 1/4" faston connector). I got the gender bender from a local Batteries Plus type store that often has to adapt between those two sizes on various rechargeable batteries.
Jay Dee
Motor City
2 years ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

works perfectly

SupplyHouse.com has become one of my "go-to" online places to shop for many plumbing, heating, and similar devices. Nice working with a place that seems like local rather than some distant, uncommunicable internet company.
justTim
West Chester, PA
2 years ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

Honeywell Intermittent Pilot Control

Standard control with a wide variety of applications to different manufacturers' products.
MikeyD
St. Paul, MN
2 years ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

yes

fast service awesome
billybob
webster wi
3 years ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

Product Q&A

18 Questions
18 Questions
ASK A QUESTION

Q: will the s8610u3009 substitute for s8600m1005 and the wiring to s8610u3009 will be the same as s8600m1005. so after connecting the s8610u i can just turn on the furnace with no problem. thank you! r

Asked by 15 years ago

Add your answer

* Required Field
Verified Author and ReplyVerified Reply- PexSupply Staff

S8610U3009 can be used to replace S8600M1005, but we are not aware of the differences (if any) in the wiring.

Was this review helpful to you?

Q: Will this replace S86A1001

Asked by 15 years ago

Add your answer

* Required Field
Verified Author and ReplyVerified Reply- PexSupply Staff

Yes, S8610U3009 is the recommended replacement for S86A1001.

Was this review helpful to you?

Q: Will this replace S8610H 1046? Thanks

Asked by 15 years ago

Add your answer

* Required Field
Verified Author and ReplyVerified Reply- PexSupply Staff

Yes, part S8610U3009 replaces the obsolete S8610H1046.

Was this review helpful to you?
- Anonymous

The Intermittent Pilot Control is a recommended field replacement unit for Honeywell model S8610H 1046.

Was this review helpful to you?
- Joe

Honeywell does not recognize this particular product. Are you sure it's S8610H 1046? I would assume the S8610U should be a good replacement. Joe

Was this review helpful to you?

Q: will this replace S86H1006

Asked by 15 years ago

Add your answer

* Required Field
Verified Author and ReplyVerified Reply- PexSupply Staff

Yes, S8610U3009 replaces part S86H1006.

Was this review helpful to you?
- Anonymous

Yes, the Honeywell S8610U3009 is a replacement for the Honeywell S86H1006 intermittent pilot control. It can also be used on most Robertshaw, Johnson, and UTEC models.

Was this review helpful to you?
- Cool Cash

Yes, This product should replace most of the S86 series Honeywell modules. To be sure, my advice is to check specs. at the Honeywell website.

Was this review helpful to you?

Q: will this replace S8600C

Asked by mike 15 years ago

Add your answer

* Required Field
Verified Author and ReplyVerified Reply- PexSupply Staff

Yes, it replaces S8600C1015 and S8600C3003.

Was this review helpful to you?

Q: Hi, Will this work as a replacement for Johnson Controls G60QHL-1 or would the Lennox 30W3301 be a better choice? Thank you.

Asked by Steve 15 years ago

Add your answer

* Required Field
Verified Author and ReplyVerified Reply- PexSupply Staff

This unit replaces the Johnson Controls G60QHL-1, according to page 5 of the following manual: http://s3.pexsupply.com/manuals/1299090484970/49449_PROD_FILE.pdf

Was this review helpful to you?

Q: hello, I have control # G776RGD-11, 63K2401 and needs to be replaced. Is this a good replacement? Thanks

Asked by ednorton 15 years ago

Add your answer

* Required Field
Verified Author and ReplyVerified Reply- PexSupply Staff

Yes, the manufacturer suggests this part as a replacement for the one you mentioned.

Was this review helpful to you?

Q: my unit is a s8610u1003 what modifications do I need to do to use this replacement unit

Asked by 16 years ago

Add your answer

* Required Field
Verified Author and ReplyVerified Reply- PexSupply Staff

The direct replacement for your unit S8610u1003 is S8610U3009. Please refer to the product page for more information: http://www.pexsupply.com/Honeywell-S8610U3009-Intermittent-Pilot-Control-4584000-p

Was this review helpful to you?
Free Shipping
On orders over $99
We offer flexible shipping and scheduling options, up-to-date delivery estimates, and free ground shipping on any order over $99 to make sure your order gets to you on-time, for less.
Shipping Policy
Easy Returns
Returning items is as simple as 1-2-3
Ordered the wrong product? Item damaged in transit? Our 3-step process makes returning products easy – even up to a year after purchase – with no restocking fees on returns made within 90 days.
Return Policy