Apply to be a TradeMaster!
Main product image of Wirsbo Joist Trak, 1/2" Heat Transfer Panel
Magnifying glass
Hover image to zoom

Wirsbo Joist Trak, 1/2" Heat Transfer Panel

SKU:
A5080500
Rating:
(104)
Q&A:
(52)
Wirsbo Joist Trak, 1/2" Heat Transfer Panel
Magnifying glass
Hover image to zoom
$10.11 each
BOX UP & SAVE 13%
$175.00 box of 20
$8.75 each
In Stock
In Stock
Get 6,497 Tue, Aug 4
Order by today, receive Tuesday
Free Shipping On orders over $99
Easy Returns No restocking fee for 90 days

Product Highlights

Product Highlight: Length (Inches)
48" Length
Product Highlight: Width (Inches)
3-1/2" Width
Product Highlight: Material
Aluminum
Product Highlight: Tubing Compatibility
PEX-a, PEX-b
Product Highlight: Height
.675"
Product Highlight: Diameter
0.640" (Internal Channel) Diameter

Description

NOTE: non-Uponor brand tubing may make noise as it expands and contracts in the Joist Trak. For best results, use Uponor Hepex.

To find out the parts and quantities you will need for your application, use our easy, quick and convenient Joist Trak Calculator.

Please note: These panels require the use of #8 screws which are not included

Use Uponor Wirsbo Joist Trak, extruded aluminum heat transfer panels, with Uponor Wirsbo 3/8" or 1/2" AQUAPEX or hePEX plus in floor joist applications. Each panel is 4 feet long by 3.5 inches wide. It provides easy installation, increased heat transfer and superior comfort.

Specs

Width (Inches):

3-1/2"

Material:

Aluminum

Tubing Compatibility:

PEX-a

PEX-b

Application:

1/2" PEX

Length (Inches):

48"

Height:

.675"

Diameter:

0.640" (Internal Channel)

Wall Thickness:

.050"

Contact

Help Face
CALL US
Question? Call or text 888-757-4774
+
Help Face

Questions?

Speak with a real person who will go out of the way to help!
Call or text 888-757-4774
MondayThursday
8am7:45pm
Friday
9am7:45pm
SaturdaySunday
9am5:45pm

Response by Tue

Need help calculating?
Use Our Calculator

Compare Similar Products

Brand
CURRENT ITEM
Product Image of Wirsbo Joist Trak, 1/2" Heat Transfer Panel
Wirsbo Joist Trak, 1/2" Heat Transfer Panel
SKU: A5080500
(104)

You May Also Need

Product Reviews

4.66 out of 104 reviews
98% would recommend this product
4.66
out of 104 Reviews
98% would recommend this product
WRITE A REVIEW
5 star
71%
4 star
26%
3 star
2%
2 star
0%
1 star
1%
WRITE A REVIEW
Customer Images

Most Liked Positive Review

Good basic product, easily improved

Installing these under a new bathroom sub-floor. In this application, heat conduction into the floor above is everything. I found the holes in the Joist-Trak to be be too small, and too few, so I drilled out the existing holes to accommodate a #10 screw, and added hole pairs between the pairs of factory holes, a bit closer to the tube channel. This should increase the conduction into the floor, and improve overall effectiveness and efficiency. I will follow up with 10" of AirKrete cementitious foam insulation to make sure all the heat goes up into the floor, not down into the room below.
VS

Most Liked Negative Review

Nope nope noooooooope!

I ended up using thin gauge snap on style plates as the Joist traks don't full cover the pex, have to be tediously screwed to floor rather than power stapled, and they are rediculously over priced. I heated a floor section side by side with these and snap over plates and couldn't tell any difference in the heating effect above the floor. The only nice thing about these are being able to install them before running pex, but otherwise not a great investment.
Showing 1-10 of 104 reviews

Properly product

Don't try to do with another product, this one it's the best one for radiant heat track above plywood.
Rcz82
Massachusetts
2 months ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

Plates work as expected.

Second time purchasing these plates for subfloor pex. They transfer heat much better than just staple up. Our home was entirely fitted with Zurn Pex B before we purchased it. Pex expansion ticking noise at cold start up is noticeable but does not last long. The factory mounting holes should be larger. I drilled ours out to accept a #8 screw. SupplyHouse pricing is competitive and shipping speed is always impressive.
Shom
Cortland, NY
4 months ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

Worked great in my application

No noise when used with Pex al Pex tubing. Worked great for radiant heating. I added aluminum sheet under floor joists then put these up as well for more heat transfer underneath the floors. Perfect set up.
CT
CT
7 months ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

Good heat conduction, sharp edges

I got these mainly to hold the tubing up against the floor until insulation could be installed. I did not expect the thin plates to provide much heat transfer, so I only used them at long intervals, enough to hold up the tubing. Later, using a thermal imager, I was surprised to see how effective the plates are - you can clearly see their outlines in the thermal images. My main concern is the sharp edges. We ran the system for some weeks before the insulation was installed (was actually surprised at how effective they were at heating before the insulation was installed). Discovered that with expansion and contraction, if the tubing did not exit the plate completely straight that the edge would abrade the tubing. So be sure to make long loops at the ends, not short ones. I became concerned about the long term prospects, so pulled the tubing down at the ends of the plates, so that the tubing exits the plate before the sharp edges. Not sure it the tubing will remain in the tract over the long term - guess I'll find out.
Old Engineer
Virginia
8 months ago
Was this review helpful to you?

Great product. No issues, works as intended.

Used it for a retrofit radiant heat project, with 1/2" pex tubing.
O
Skokie, IL
9 months ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

Easiest to use

Under sub floor thermal heating.
Bob
Williamstown, VT
12 months ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

I would buy this again

We used thousands of these panels. They work very well if they are installed per spec. You must insulate under the joist where panels are located to perform the best.
Airflow
Chicago IL
1 years ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

I would buy these again.

Fast delivery and easy to install.
Doug
NH
3 years ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

Perfect for underfloor heating zone retrofits.

As described, works w the Special heat transfer PEX tubing. Added hot water heat zones to my daughter's bedroom, bathroom, and kitchen floor.
D. Oneil
Pittsburgh, PA
3 years ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

Good product with excellent customer service

I have purchased this product before and wanted to expand my floor heating system. I order 14 but received 12. I called customer service and they shipped the missing 2 right away, helping me complete the project with minimal delay. Never have I had a bad experience dealing with Supplyhouse!
Enga-guy Keith
Engadine Mi
4 years ago
Verified Buyer Icon
Verified Buyer
Was this review helpful to you?

Product Q&A

52 Questions
52 Questions
ASK A QUESTION

Q: Q1: Any recomendation on spacing of the Heat Transfer Panels under a subfloor of 3/4 inch, plus 3/4 inch of plywood on top, plus a 1/2 inch for flooring (ie. 1.5 inches of plywood plus 1/2 of flooring?) Q2: Is cork flooring an option when using Heat Transfer Panels under a subfloor regarding heat transfer and comfort?

Asked by 15 years ago

Add your answer

* Required Field
Verified Author and ReplyVerified Reply- PexSupply Staff

Proper spacing is based on joist bay size. The cork will slow the heat from coming up, so you have to account for that when designing your system.

Was this review helpful to you?

Q: house built around 1865. joist spacing varies in different areas from 8", 12" and 16" depending on the span. would I need to put in 2 trak's in each bay?

Asked by Tom 15 years ago

Add your answer

* Required Field
Verified Author and ReplyVerified Reply- PexSupply Staff

We would recommend that you put two traks in the 12" and 16" bays.

Was this review helpful to you?

Q: Can I use this trak under 3/4" sub floor with 3/4 tongue and groove fir over top of it? Should I space the pex lines closer together (12") to increase the heat gain and defeat the insulating property of 1.5" of wood? Thanks

Asked by Homemade 15 years ago

Add your answer

* Required Field
Verified Author and ReplyVerified Reply- PexSupply Staff

Joist Trak panels are meant to be used under the sub-floor in the joist bays.

Was this review helpful to you?

Q: im am being put of from using the product as people are telling me about squeaking noises.i want to heat 1500 sqft and cant screw it up ,is joist trak the right material to use

Asked by 15 years ago

Add your answer

* Required Field
Verified Author and ReplyVerified Reply- PexSupply Staff

Any squeaking noises come from the metal expanding. They are generally only an issues when installers do not secure the panels using all the screw holes.

Was this review helpful to you?

Q: When our radiant heating system was installed years ago, there were only plastic hangers used to attach the PEX tubing. I'd like to add the heat transfer panels to make the existing system more efficient and even out the floor temp. However, since it's a 100+ year old house, the wood flooring is not laid on subfloor but directly on the floor joists. Would the transfer panels make the wood flooring too hot?

Asked by DDCC 15 years ago

Add your answer

* Required Field
Verified Author and ReplyVerified Reply- PexSupply Staff

The panels would not make the wood flooring too hot as long as the water temperature is below 140°F and the surface temperature is below 82°F.

Was this review helpful to you?

Q: Can I use spray foam directly over the panels and tubing (need some kind of vapour barrier in this application) or should there be an air space between the floor and insulation in the joist space?

Asked by 15 years ago

Add your answer

* Required Field
Verified Author and ReplyVerified Reply- PexSupply Staff

No gap is necessary. You can use spray foam with these panels.

Was this review helpful to you?

Q: when installing joist track under 3/4" hardwood does the hardwood have to be installed first to prevent nails from hitting the pex or does the joist track maintain enough room so the nails or stapels won't hit the pex pipe?

Asked by John 15 years ago

Add your answer

* Required Field
Verified Author and ReplyVerified Reply- PexSupply Staff

We recommend that you install the floor first.

Was this review helpful to you?

Q: how many btu's are taken from pex tubing per 4' panel?

Asked by klem 15 years ago

Add your answer

* Required Field
Verified Author and ReplyVerified Reply- PexSupply Staff

The maximum BTU transfer with these panels is 35 BTU/square foot in the floor and 45 BTU/square foot in the ceiling.

Was this review helpful to you?

Q: Do these transfer panels come in 8' lengths?

Asked by Lugnut 15 years ago

Add your answer

* Required Field
Verified Author and ReplyVerified Reply- PexSupply Staff

No, they are only available in 4' lengths at this time.

Was this review helpful to you?

Q: Will I get heat thru 3/4" advantec with another layer of 1/2" plywood and a layer of carpeting, if I use radiant panels. How much material can radiant heat penetrate thru and still be effective?

Asked by Mark 15 years ago

Add your answer

* Required Field
Verified Author and ReplyVerified Reply- PexSupply Staff

You are not going to get the greatest amount of heat through the insulation of all those layers. The rate would be based on the BTU load of the space, the R-valve that needs to be overcome, and the water temperature of the system.

Was this review helpful to you?
Free Shipping
On orders over $99
We offer flexible shipping and scheduling options, up-to-date delivery estimates, and free ground shipping on any order over $99 to make sure your order gets to you on-time, for less.
Shipping Policy
Easy Returns
Returning items is as simple as 1-2-3
Ordered the wrong product? Item damaged in transit? Our 3-step process makes returning products easy – even up to a year after purchase – with no restocking fees on returns made within 90 days.
Return Policy