| Width (Inches): | 3-1/2" |
|---|---|
| Material: | Aluminum |
| Tubing Compatibility: | PEX-a PEX-b |
| Application: | 1/2" PEX |
| Length (Inches): | 48" |
| Height: | .675" |
| Diameter: | 0.640" (Internal Channel) |
| Wall Thickness: | .050" |
Yes, we would recommend that. We recommend an R value of 19.
No, it will not work.
Yes, you can use it for the application you describe.
No, you will need to lower the water temperature down. The maximum temperature you can run is 170 degrees F.
For this installation, no air gap is required. You can spray the foam insulation in the joist cavity and right onto the panel and tubing.
If the panel you mean is a Joist Trak, no air space is needed; you want to transfer from Pex to aluminum to sub-floor without heat loss through air. Air space IS needed if no Joist Trak is used and the Pex is heating an air space (about 2" I believe); here specific insulation is required. As for using spray foam, I don't know the specifics of the insulation or the humidity of the crawl space so I cannot rule out the possibility of trapped moisture causing wood to decay.
You will need 2 lines per joist, one going and one returning. It will provide an even distribution to prevent any cold spots in the floor.
When installing Joist Traks, you need to leave a 1" to 3" gap between each panel. Find out how much tubing you will need for your Joist Trak project using our Joist Trak calculator: http://calculators.pexsupply.com/quik_trak_calc_step1.asp
For a 14 Square Foot area you would need 3 pieces of Joist Trak and 14 ft. tubing. The parts would be between each Joist. The panels can be spaced 12", 16", or 18" apart.
The Joist Trak Panels should be mounted beneath the wood subfloor. For example, for a standard ground floor application, you will have to mount and nail these units on the ceiling of the basement to feel the heat on the floor above. The Joist Trak can be attached to the wood subfloor using #8 screws. Be sure to use a screw that is shorter than the subfloor so that it does not go through.
The Joist Trak Panels should be mounted beneath the wood subfloor. For example, for a standard ground floor application, you will have to mount these units on the ceiling of the basement to feel the heat on the floor above.