Apply to be a TradeMaster!
Filter menu expanded

Filters

1,206 items
Reset

SORT

Product Availability

Show In Stock Only (587)

Amperage

2.5 (2)
3 (2)
5 (4)
6 (2)
7 (5)
9 (29)
10 (17)
12 (21)
15 (3)
17 (1)

Voltage

12v (1)
12-250 V (1)
24 VAC (4)
24 VDC (4)
24-240V AC/DC (1)
24V (182)
36V (1)
50-129V AC/DC (1)
100V (1)
110v (69)

Poles

1 (72)
1.5 (15)
2 (160)
3 (471)
4 (51)
5 (1)
6 (5)
8 (5)
10 (2)
12 (2)

Review Score

(95)
(8)
(3)
(2)

Price Range

$5 to $10 (11)
$10 to $15 (52)
$15 to $20 (45)
$20 to $25 (52)
$25 to $30 (43)
$30 to $35 (60)
$35 to $40 (82)
$40 to $45 (46)
$45 to $50 (30)
$50 to $60 (66)

Electrical Contactors

Help Face
Need a little help?
1206 items
Grid
List
Compare
Product Image of 1NO Freedom Auxiliary Contact, Side Mount
1NO Freedom Auxiliary Contact, Side Mount
SKU: C320KGS41
Eaton
SKU: C320KGS41
Brand: Eaton
$135.42 each
In Stock
Get 1 by Wed, Aug 19
In Stock
Get 1 by Wed, Aug 19
Compare
Product Image of Auxiliary Contact Kit 10A, 1 NO & 1 NC
$102.82 each
In Stock
Get 2 by Tue, Aug 18
In Stock
Get 2 by Tue, Aug 18
Compare
Product Image of 3 Pole, 12 Amp, 110/120V Power Contactor
3 Pole, 12 Amp, 110/120V Power Contactor
SKU: 3RT2017-1AK62
Siemens
SKU: 3RT2017-1AK62
Brand: Siemens
$109.52 each
In Stock
Get 1 by Wed, Aug 19
In Stock
Get 1 by Wed, Aug 19
Compare
Product Image of 3 Pole, 9 Amp, 230V Power Contactor
3 Pole, 9 Amp, 230V Power Contactor
SKU: 3RT2016-1AP01
Siemens
SKU: 3RT2016-1AP01
Brand: Siemens
$88.42 each
In Stock
Get 2 by Tue, Aug 18
In Stock
Get 2 by Tue, Aug 18
Compare
Product Image of 1 Pole Contactor, 120 VAC Coil, 50/60 Hz, 30 Amp Contacts. Coil Data: 420 Ohms DC Resistance, 42 mA
$30.13 each
In Stock
Get 18 by Wed, Aug 19
In Stock
Get 18 by Wed, Aug 19
Compare
Product Image of TeSys D IEC Non-Reversing Contactor (9A Inductive/20A Resistive, 110V AC Coil, 3P)
$142.28 each
In Stock
Get 1 by Tue, Aug 18
In Stock
Get 1 by Tue, Aug 18
Compare
Product Image of Contactor, 18A (24V)
Contactor, 18A (24V)
SKU: LC1D18BD
Square D
SKU: LC1D18BD
Brand: Square D
(1)
$179.84 each
In Stock
Get 2 by Wed, Aug 19
In Stock
Get 2 by Wed, Aug 19
Compare
Product Image of 24 Vac 3 Pole PowerPro Deluxe Definite Purpose Contactor w/ Lug Connectors, DP3060A5001
$152.52 each
In Stock
Get 1 by Tue, Aug 18
In Stock
Get 1 by Tue, Aug 18
Compare
Product Image of 208V NEMA Size 1 Non-Reversing Contactor, 3 Poles, Open Style (27A)
$488.01 each
In Stock
Get 2 by Tue, Aug 18
In Stock
Get 2 by Tue, Aug 18
Compare
Product Image of Mechanical Interlock, Horizontal Mount
Mechanical Interlock, Horizontal Mount
SKU: C321KM30
Eaton
SKU: C321KM30
Brand: Eaton
$164.78 each
In Stock
Get 1 by Tue, Aug 18
In Stock
Get 1 by Tue, Aug 18
Compare
Product Image of Side Mount NO/NC Aux Switch
Side Mount NO/NC Aux Switch
SKU: 3RH2921-1DA11
Siemens
SKU: 3RH2921-1DA11
Brand: Siemens
$56.16 each
In Stock
Get 22 by Wed, Aug 19
In Stock
Get 22 by Wed, Aug 19
Compare
Product Image of 120v 40a Contactor 3 No, Dp40c3p-1
120v 40a Contactor 3 No, Dp40c3p-1
SKU: DP40C3P-1
ABB
SKU: DP40C3P-1
Brand: ABB
$125.24 each
In Stock
Get 1 by Wed, Aug 19
In Stock
Get 1 by Wed, Aug 19
Compare
Product Image of 4 Pole  N/O Definite Purpose Contactor, 30A (24V)
4 Pole N/O Definite Purpose Contactor, 30A (24V)
SKU: 8910DPA34V14
Square D
SKU: 8910DPA34V14
Brand: Square D
$147.81 each
In Stock
Get 2 by Tue, Aug 18
In Stock
Get 2 by Tue, Aug 18
Compare
Product Image of 3p 68a 100-250vac/dc 1 No 1 Nc, Af65-30-11-13
3p 68a 100-250vac/dc 1 No 1 Nc, Af65-30-11-13
SKU: AF65-30-11-13
ABB
SKU: AF65-30-11-13
Brand: ABB
$389.55 each
In Stock
Get 1 by Wed, Aug 19
In Stock
Get 1 by Wed, Aug 19
Compare
Product Image of 60a 120v 3p Contactor, Dp60c3p-1/pb
60a 120v 3p Contactor, Dp60c3p-1/pb
SKU: DP60C3P-1/PB
ABB
SKU: DP60C3P-1/PB
Brand: ABB
$283.46 each
In Stock
Get 2 by Wed, Aug 19
In Stock
Get 2 by Wed, Aug 19
Compare
Product Image of 3 Pole Contactor, NC & NO 24VDC, TeSys Deca, LC1D09BD
$142.75 each
In Stock
Get 6 by Tue, Aug 18
In Stock
Get 6 by Tue, Aug 18
Compare
Product Image of Solid-State-Compatible Auxiliary Contact Switch Block, 1NO/1NC, for 3RH & 3RT Contactors
$99.20 each
In Stock
Get 5 by Wed, Aug 19
In Stock
Get 5 by Wed, Aug 19
Compare
Product Image of Contactor with Auxiliary, 3P, 12A (24V)
Contactor with Auxiliary, 3P, 12A (24V)
SKU: LC1D12B7
Square D
SKU: LC1D12B7
Brand: Square D
(1)
$196.61 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of 5 Amp, Electrical Switch Contact Block 600 VAC, For Type B Pushbutton Station, 9001BOC368
$76.78 each
In Stock
Get 3 by Fri, Aug 21
In Stock
Get 3 by Fri, Aug 21
Compare
Product Image of 1 Pole DP Contactor, 120 Volt Coil, 30 Amp
$14.99 each
In Stock
Get 2 by Thu, Aug 20
In Stock
Get 2 by Thu, Aug 20
Compare
Product Image of Definite Purpose Contactor, 2P, 30A (24/24V)
Definite Purpose Contactor, 2P, 30A (24/24V)
SKU: 8910DPA32V14
Square D
SKU: 8910DPA32V14
Brand: Square D
(1)
$105.40 each
In Stock
Get 3 by Wed, Aug 19
In Stock
Get 3 by Wed, Aug 19
Compare
Product Image of 3 Pole Contactor w/ Box Lug Termination (75A, 208-240V)
$376.75 each
In Stock
Get 3 by Tue, Aug 18
In Stock
Get 3 by Tue, Aug 18
Compare
Product Image of 3-Pole Definite Purpose Contactor (24V, 15 Amp)
3-Pole Definite Purpose Contactor (24V, 15 Amp)
SKU: C25DND315T
Eaton
SKU: C25DND315T
Brand: Eaton
$209.01 each
In Stock
Get 1 by Tue, Aug 18
In Stock
Get 1 by Tue, Aug 18
Compare
Product Image of 3 Pole, 12 Amp, 24V Power Contactor
3 Pole, 12 Amp, 24V Power Contactor
SKU: 3RT2017-1BB41
Siemens
SKU: 3RT2017-1BB41
Brand: Siemens
$146.07 each
In Stock
Get 3 by Wed, Aug 19
In Stock
Get 3 by Wed, Aug 19
Compare
Product Image of 3 Pole, 32 Amp, 1NO/1NC, 230V Power Contactor
3 Pole, 32 Amp, 1NO/1NC, 230V Power Contactor
SKU: 3RT2027-1AL20
Siemens
SKU: 3RT2027-1AL20
Brand: Siemens
$285.54 each
In Stock
Get 2 by Fri, Aug 21
In Stock
Get 2 by Fri, Aug 21
Compare
Product Image of 208/240 VAC 2 Pole PowerPro Deluxe Definite Purpose Contactor (30 A), DPL2030C5011
$46.29 each
Out of Stock
Get it by Tue, Sep 1 - Wed, Sep 9
Out of Stock
Get it by Tue, Sep 1 - Wed, Sep 9
Compare
Product Image of 2 Pole Contactor (120V, 25 Amp)
2 Pole Contactor (120V, 25 Amp)
SKU: C225B
Packard
SKU: C225B
Brand: Packard
$13.51 each
In Stock
Get 5 by Tue, Aug 18
In Stock
Get 5 by Tue, Aug 18
Compare
Product Image of 3 Pole Contactor with 2 Auxiliary, 32A (110V)
$262.46 each
In Stock
Get 4 by Wed, Aug 19
In Stock
Get 4 by Wed, Aug 19
Compare
Product Image of 2 Pole DP Contactor, 120 Volt Coil, 25 Amp
$17.99 each
In Stock
Get 1 by Tue, Aug 18
In Stock
Get 1 by Tue, Aug 18
Compare
Product Image of TeSys D Non-Reversing Contactor (65A Inductive/80A Resistive, 24V AC Coil, 3P)
$465.53 each
In Stock
Get 1 by Tue, Aug 18
In Stock
Get 1 by Tue, Aug 18
Compare
Product Image of Contactor Thermal Unit, A11.0
Contactor Thermal Unit, A11.0
SKU: A11.0
Square D
SKU: A11.0
Brand: Square D
$39.09 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Auxiliary Contact Block, 1N/O 1N/C (Front Plate Mounting, 10A, 660V)
Auxiliary Contact Block, 1N/O 1N/C (Front Plate Mounting, 10A, 660V)
SKU: 3SU1400-1AA10-1FA0
Siemens
SKU: 3SU1400-1AA10-1FA0
Brand: Siemens
$32.64 each
In Stock
Get 1 by Wed, Aug 19
In Stock
Get 1 by Wed, Aug 19
Compare
Product Image of 1NC Freedom Auxiliary Contact, Side Mount
1NC Freedom Auxiliary Contact, Side Mount
SKU: C320KGS21
Eaton
SKU: C320KGS21
Brand: Eaton
$135.42 each
In Stock
Get 1 by Tue, Aug 18
In Stock
Get 1 by Tue, Aug 18
Compare
Product Image of 3-Pole Definite Purpose Contactor (110/24V, 40 Amp)
3-Pole Definite Purpose Contactor (110/24V, 40 Amp)
SKU: C25DNY162T
Eaton
SKU: C25DNY162T
Brand: Eaton
(1)
$123.81 each
In Stock
Get 3 by Tue, Aug 18
In Stock
Get 3 by Tue, Aug 18
Compare
Product Image of 3-Pole NEMA Non-Reversing Motor Control Contactor, Full Voltage, Size 2 (120/110V, 45 Amp)
$1,412.18 each
In Stock
Get 1 by Tue, Aug 18
In Stock
Get 1 by Tue, Aug 18
Compare
Product Image of 3-Pole Definite Purpose Contactor (110/120V, 40 Amp)
$173.96 each
In Stock
Get 1 by Tue, Aug 18
In Stock
Get 1 by Tue, Aug 18
Compare
Product Image of 1 N.O./1 N.C. Auxiliary Contact Block Contactor , 2P (690V)
$32.17 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of 3-Pole Non-Reversing Contactor (24V, 9 Amp)
3-Pole Non-Reversing Contactor (24V, 9 Amp)
SKU: XTCE009B10T
Eaton
SKU: XTCE009B10T
Brand: Eaton
$109.74 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Mechanical Interlock for Reversing Contactor Assembly, Size S2-S3, Side Mount
$21.47 each
In Stock
Get 3 by Wed, Aug 19
In Stock
Get 3 by Wed, Aug 19
Compare
Product Image of 2 Pole Contactor (208/240V, 25 Amp)
$13.56 each
In Stock
Get 1 by Tue, Aug 18
In Stock
Get 1 by Tue, Aug 18
Compare
Product Image of Easy TeSys DPE Auxiliary Contact Block, 1NO/1NC w/ Screw Clamp Terminals & Push Button
$11.25 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of 3 Pole Non-Reversing Contactor, 20 AMP (480V)
$104.55 each
In Stock
Get 2 by Wed, Aug 19
In Stock
Get 2 by Wed, Aug 19
Compare
Product Image of 1-1/2 Pole Definite Purpose Contactor (25A, 24V)
$14.73 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of TeSys D Non-Reversing Contactor (32A Inductive/50A Resistive, 208V AC Coil, 3P)
$271.71 each
In Stock
Get 1 by Wed, Aug 19
In Stock
Get 1 by Wed, Aug 19
Compare
Product Image of 110-120V/220-240V Coil NEMA Sz 3+3.5
110-120V/220-240V Coil NEMA Sz 3+3.5
SKU: 75D73251A
Siemens
SKU: 75D73251A
Brand: Siemens
$319.25 each
In Stock
Get 1 by Wed, Aug 19
In Stock
Get 1 by Wed, Aug 19
Compare
Product Image of 24vac 40a Contactor, Dp40c3p-f
24vac 40a Contactor, Dp40c3p-f
SKU: DP40C3P-F
ABB
SKU: DP40C3P-F
Brand: ABB
$116.30 each
In Stock
Get 2 by Wed, Aug 19
In Stock
Get 2 by Wed, Aug 19
Compare
Product Image of Front Mount Auxiliary 2 No/2 Nc, Ca4-22e
Front Mount Auxiliary 2 No/2 Nc, Ca4-22e
SKU: CA4-22E
ABB
SKU: CA4-22E
Brand: ABB
$41.15 each
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Backorder
Get it by Wed, Sep 16 - Wed, Oct 14
Compare
Product Image of Normally Open Contact Block, ZBE101
$9.63 each
Out of Stock
Get it by Tue, Sep 1 - Wed, Sep 9
Out of Stock
Get it by Tue, Sep 1 - Wed, Sep 9
Resources
FAQs, Manuals & Videos
Articles
More About Contactors

Contactors are electromechanical switches that use a low-voltage control signal to open and close a higher-voltage power circuit, most commonly the circuit that feeds a compressor, condenser fan motor, or other large HVAC or electrical load. A thermostat or control board sends a small signal to energize the contactor's coil, which pulls a set of contacts together and completes the high-voltage circuit without routing that heavier current through the control wiring itself. HVAC technicians replace contactors more often than almost any other electrical component in a split system, since the contacts see repeated arcing every time the compressor or fan cycles on and off. A pitted, burned, or stuck contactor is a common cause of equipment that will not start, that hums without running, or that keeps running after the thermostat is satisfied. Contactors are sized by coil voltage, number of poles, and current rating, and matching all three to the application is what keeps a replacement working safely in place of the original.

Subcategories

  • Single-Pole Contactors: Single-pole contactors switch one leg of the power circuit while the other leg stays connected directly, a configuration common on smaller residential condensing units and single-phase loads. They cost less and take up less panel space than multi-pole versions, which makes them a common original-equipment choice on lighter-duty equipment. Technicians confirm the coil voltage and current rating match the original part before swapping one in, since an undersized contactor will fail quickly under the same load. Single-pole units are typically the most frequently replaced contactor type on residential service calls.
  • Double-Pole and Two-Pole Contactors: Double-pole contactors switch both legs of a two-wire power circuit simultaneously, fully disconnecting the load rather than leaving one leg energized. This configuration is common on larger residential and light commercial condensing units where fully isolating the compressor circuit is the standard design approach. Replacing a double-pole contactor with a single-pole unit is not a safe substitution even if the coil voltage matches, since the circuit design depends on both legs switching together. Technicians check the original wiring diagram when the pole configuration is not obvious from the failed part alone.
  • Three-Pole Contactors: Three-pole contactors switch all three legs of a three-phase power circuit, a configuration used almost exclusively on commercial and light industrial HVAC equipment rather than typical residential split systems. Failure symptoms mirror single and double-pole units, including pitted contacts, a stuck armature, or a coil that no longer pulls in reliably. Because three-phase equipment often carries higher current loads, three-pole contactors are built with heavier contact material to handle the added electrical stress. Matching current rating and coil voltage remains the deciding factor when selecting a replacement, the same as with lower pole-count contactors.
  • Definite Purpose Contactors: Definite purpose contactors are built specifically for a narrow range of applications, most often HVAC compressor and fan loads, rather than the broader industrial control uses that a general-purpose contactor covers. Their compact size and simplified mounting make them the standard choice for residential and light commercial condensing unit replacement work. Technicians stock definite purpose contactors in the most common voltage and pole configurations since these cover the large majority of service calls. Choosing a definite purpose model built for the specific application avoids paying for features meant for industrial control panels that a condensing unit will never use.

Buying Guide

Matching a replacement contactor to the failed original starts with three specifications: coil voltage, number of poles, and full-load or resistive current rating. Coil voltage refers to the low-voltage signal that energizes the contactor, commonly a value supplied by the control transformer, and it needs to match exactly since a contactor with the wrong coil voltage either will not pull in or will burn out quickly from overvoltage. Pole count determines how many legs of the power circuit the contactor switches, and current rating determines how much load the contacts can handle without excessive arcing or premature failure.

Physical size and terminal configuration matter for a clean installation, since Contactors mount inside a tight electrical compartment where a slightly larger or differently shaped replacement may not fit the existing bracket or wiring layout without modification. Comparing the physical footprint of a proposed replacement against the failed part before ordering avoids a return trip when the new contactor does not clear the panel enclosure.

Technicians working service routes across a mix of residential and light commercial equipment generally keep the most common single-pole and double-pole configurations on the truck, since these cover the majority of everyday calls. Three-pole contactors and less common voltage combinations are usually ordered once the specific unit's requirements are confirmed on site rather than stocked in bulk, since commercial three-phase equipment makes up a smaller share of most residential-focused service work.

Frequently Asked Questions

What are the signs that a contactor needs to be replaced?

A unit that hums but will not start, a compressor or fan that keeps running after the thermostat is satisfied, or visible pitting and burn marks on the contacts all point toward a failing contactor. A contactor that chatters or buzzes audibly when energized is also a common warning sign. Testing the coil for continuity and checking the contacts for excessive wear confirms the diagnosis before ordering a replacement.

How is coil voltage different from the contactor's power circuit voltage?

Coil voltage is the low-voltage signal, typically supplied through the control transformer, that energizes the contactor and pulls the contacts together. The power circuit voltage is the separate, usually much higher, voltage that the contacts switch on and off to run the compressor or fan motor. Both values need to be checked separately since matching one without the other will not produce a working replacement.

Can a single-pole contactor be replaced with a double-pole model?

A double-pole contactor can generally replace a single-pole unit as long as coil voltage and current rating match, since the extra pole simply switches the additional leg without disconnecting anything unusual. The reverse substitution, replacing a double-pole contactor with a single-pole unit, is not safe since it leaves one leg of the circuit energized when it should be fully disconnected. Checking the original wiring diagram before making the swap avoids this mistake.

Why do HVAC contactors fail more often than other electrical components?

Contactors switch a large electrical load every time the compressor or fan cycles on and off, and that repeated arcing gradually wears down the contact material until the connection becomes unreliable. Units that cycle frequently, such as during a hot summer with heavy air conditioning use, put more cumulative wear on the contactor than equipment that runs for longer, less frequent cycles. This wear pattern makes contactors one of the most commonly replaced parts in HVAC service work.

Is it safe to bypass a failed contactor temporarily?

Bypassing a contactor removes the low-voltage control point that allows the thermostat to safely start and stop the compressor or fan, which creates both a safety hazard and a risk of equipment damage from uncontrolled operation. A temporary bypass is not a substitute for a proper repair and should not be left in place beyond diagnosing the fault. Replacing the failed contactor with a correctly matched part is the only reliable fix.