Siemens Globe Valves are linear stroke control valves used to modulate hot water, chilled water, and low-pressure steam flow across HVAC heating and cooling systems, available in sizes from 1/2 inch up to 6 inches to cover everything from a single zone valve to a large air handler coil. The Flowrite line within this category rates to 200 PSI high close-off and offers 100 to 1 rangeability, giving a controls technician fine adjustment across the full stroke without a dead band gap in flow control. Siemens offers the 599 Series in both brass and stainless steel body construction, in two way and three way configurations, and in normally open or normally closed action, with Cv ratings spanning from 0.4 up to 10 across the 1/2 inch and 3/4 inch sizes commonly used on zone and mixing applications. Field repairable construction on the Flowrite line lets a technician rebuild a valve in place rather than replacing the full body, which keeps a service call shorter on an older mechanical room retrofit.
Subcategories
Buying Guide
Choosing the right valve body starts with flow configuration, since a two way valve throttles a single path while a three way valve mixes or diverts flow between two circuits, and swapping one for the other on a retrofit usually means changing the piping layout too. Cv rating comes next, and matching it to the coil or zone load prevents an oversized valve from hunting near the closed position or an undersized valve from starving flow at full open. Body material depends on water chemistry more than budget alone. Brass bodies cover typical closed loop heating water systems, while stainless steel construction holds up better against glycol content or more aggressive water treatment chemicals found in some chilled water loops. Actuation type, normally open or normally closed, determines what the valve does on a power or signal loss, so confirming which failsafe position a zone needs before ordering avoids a callback after a controls failure. Siemens Globe Valves in the 599 Series also come in different connection styles, including female by female and female by union male, so checking existing pipe thread and union hardware against the new valve body avoids a return trip mid installation. For larger coils or air handlers approaching the top of the size range, the Flowrite platform's 200 PSI close-off rating and 100 to 1 rangeability keep control tight across the full stroke rather than just near wide open, which matters most on variable flow systems with aggressive setpoint changes.
Frequently Asked Questions
What is the difference between a 2-way and 3-way Siemens globe valve?
A 2-way Siemens globe valve throttles flow through a single path, opening or closing to regulate delivery to a coil or zone. A 3-way version mixes or diverts flow between two circuits, commonly used on mixing stations that blend supply and return water to hit a setpoint temperature. Piping layout differs between the two configurations, so a straight swap from one to the other on a retrofit usually requires repiping the connection.
What Cv rating do I need for a Siemens globe valve?
Cv rating on Siemens Globe Valves in the 599 Series ranges from 0.4 up to 10 across common 1/2 inch and 3/4 inch sizes, with larger sizes available up to 6 inches in the broader product line. Matching Cv to the coil or zone load keeps the valve from hunting near closed on an oversized selection or starving flow at full open on an undersized one. Checking the original equipment manufacturer's coil flow requirement before ordering keeps the replacement valve sized correctly.
Should a Siemens globe valve be brass or stainless steel?
Brass body construction covers typical closed loop heating water systems where cost matters more than corrosion resistance. Stainless steel construction holds up better against glycol content and more aggressive water treatment chemicals often found in chilled water loops. Checking system water chemistry against the manufacturer's material recommendation before ordering avoids premature valve wear.
What does normally open versus normally closed mean on these valves?
Normally open and normally closed describe the valve's failsafe position when power or control signal is lost. A normally open valve defaults to flowing, which suits zones that need heat or cooling to continue during a controls fault. A normally closed valve defaults to shut, which suits zones where continued flow during a fault would cause a problem. Confirming the required failsafe position before ordering avoids a callback after installation.
What is the maximum pressure rating for Siemens globe valves?
The Flowrite platform within the Siemens globe valve line rates to 200 PSI high close-off, with 100 to 1 rangeability across the full stroke. Sizes run from 1/2 inch up to 6 inches, covering everything from a single zone valve to a large air handler coil. Confirming system operating pressure against this rating before ordering keeps the valve within its designed close-off range.