| Tank Volume: | 32 Gallons |
|---|---|
| Max Accept. Factor: | 0.35 |
| Connection Size: | 1" |
| Precharged PSI: | 38 psi |
| Max Pressure (PSI): | 150 |
| Height (Inches): | 45" |
| Diameter (Inches): | 15-3/8" |
| Weight (lbs): | 43 lbs |
| Warranty: | 7 Year Limited |
| Max Temp (F): | 200°F |
| Coating: | Blue Enamel |
| Shell Material: | Steel |
| Diaphragm Material: | Heavy Duty Butyl |
| Liner Material: | Virgin Polypropylene |
| Application: | Plumbing |
The WX-203 has an 8.6 gallon draw down at 40/60.
The unit comes pre-charged to 38 PSI. Release or add air as necessary to make the precharge pressure 2 psig below the pressure switch pump cut-in setting.(Example, if you have aWX-202-XL with a precharge of 38psig, and you have a pressure switch setting of 30/50 psig, adjust pre-charge of your WX-202-XL from 38 psig to 28 psig.) For more information please see pg 5 here: http://s3.supplyhouse.com/manuals/1327104462397/70495_PROD_FILE.pdf
we do not have that information, it would be best to contact Amrtrol directly for technical questions
the problem is most likely the air pressure setting in the tank. If your switch comes on at 40 psi you should have 37-38 psi of air pressure in the tank/bladder when all of the water pressure is off the system. Start by turning off the power/beaker to the pump open a faucet in the house & let it run until no water is coming out. Take a tire gauge & measure the amount of air that is in the tank it should be 37-38 psi if the switch closes at 40 psi. adjust the air pressure as needed close the faucet & restart the the pump you should notice a lot longer cycle time. When you have the pressure drained if there is still water in the tank the bladder is most likely ruined.
the exact size is listed on this spec sheet. http://s3.supplyhouse.com/manuals/1327104501242/70497_PROD_FILE.pdf
The WX-203 is a similar unit to the 203LTD and would make a good candidate to replace it.
The distance from the floor to the center of the water hookup is 1-15/16".
Yes, WX-203 tanks do include a stand.
Yes, the DURABASE-15 stand will work with this tank. Part WX-203D includes the WX-203 tank and the durabase stand.
The connection is 1 inch,
Yes, this tank has a drain valve attached to the unit.