Uponor (Wirsbo) TruFLOW manifolds are distribution manifolds used to split and balance water flow across multiple loops in a radiant heating or plumbing system built with PEX tubing. Each outlet on the manifold includes a flow meter that lets an installer visually set and verify the flow rate to that specific loop, which matters when a system has loops of different lengths or heat loads feeding from the same source. Radiant heat installers rely on this kind of balancing to keep floor temperatures even across a large slab or multiple rooms fed from one manifold station. A manifold typically mounts in a mechanical room or closet close to the boiler or manifold cabinet, with individual PEX lines running out to each zone of the building. Because balancing happens at the manifold rather than at each individual loop's endpoint, a technician can adjust and diagnose flow issues from a single, accessible location.
Subcategories
Buying Guide
Sizing a manifold starts with counting the number of radiant loops or zones that need to feed from one location. A manifold with too few outlets forces a job to use multiple manifold stations where one larger unit might have worked, while an oversized manifold adds unnecessary cost and takes up more cabinet space than needed. Reviewing the full floor plan and loop layout before ordering helps determine the right outlet count.
Flow balancing capability is a central feature of a TruFLOW-style manifold, since each loop in a radiant system often has a different length and heat demand. A manifold with visible, adjustable flow meters at each outlet lets an installer set and verify flow without needing separate balancing valves elsewhere in the system. That visibility also makes troubleshooting easier down the road if one zone is not heating evenly.
Uponor (Wirsbo) TruFLOW Manifolds also need to match the PEX tubing size and connection style already specified for the job, since fitting adapters vary by tubing diameter and connection method. Confirming compatibility between the manifold's outlet fittings and the PEX tubing and tools already on hand avoids a mismatched parts order and keeps the installation on schedule.
Frequently Asked Questions
What does a flow meter on a manifold outlet actually do?
A flow meter shows the rate of water moving through that specific loop, usually with a visible float or indicator inside a clear sight tube. Adjusting the meter changes how much flow reaches that loop relative to the others on the same manifold. Balancing each loop this way helps even out room temperatures across a radiant system with loops of different lengths.
How many loops can connect to one manifold?
Manifold outlet counts vary by model, and the right size depends on how many individual radiant loops or zones need to feed from that station. Counting the loops planned for a project before ordering helps avoid choosing a manifold that is too small or larger than necessary. Multiple manifold stations can be used together on larger projects with more loops than a single manifold can handle.
Do supply and return manifolds need to be replaced together?
Supply and return manifolds typically work as a matched pair in a single installation, but a return manifold can sometimes be serviced or replaced independently if only that side has failed. Confirming compatibility between the existing manifold and any replacement part avoids a mismatch in connection style or outlet count. Keeping both halves from the same product line simplifies future service.
Can isolation valves be added to a manifold that does not already have them?
Some manifold models accept accessory isolation valves at each outlet, while others come with valves built in from the factory. Checking the specific manifold model's accessory compatibility before ordering separate valves prevents a fitment issue. Isolation valves make it possible to shut down and service a single loop without draining the entire radiant system.
What size PEX tubing works with a TruFLOW-style manifold?
Manifold outlet fittings are sized to match specific PEX tubing diameters, and the connection style needs to correspond to the tubing and tools already used on the job. Confirming the manifold's outlet fitting size against the tubing diameter before ordering avoids a mismatched connection. Adapters are available in some cases to bridge between different fitting styles.