Dwyer Pressure Controls are pressure switches and related regulator accessories used to sense, set, and control pressure in HVAC and process applications. The category includes SPDT switches with low water column ranges, such as a single and dual pressure switch with a .15 to 1.5 inch w.c. range and a large diaphragm model with a .20 to 1.0 inch w.c. range. Dwyer lists air and non-combustible, compatible gases as the service for both of those switches. The category also includes a panel mount nut for the Series MPR miniature pressure regulator, which Dwyer describes as a compact unit for compressed air or air/water. Selecting the correct range and switch action matters because a control only performs as intended when its set point sits within the rated span for the application.
Subcategories
Buying Guide
Start with the pressure range. The switches in this category cover low water column spans, including .15 to 1.5 inch w.c. on the single and dual switch and 1.0 to 4.0 inch w.c. on the Series 1640 null switch. Choose the model whose adjustable span covers the set point the application needs, and keep the set point comfortably within that span rather than near its limits.
Next, match the switch action and the electrical load. All of the switches reviewed here are SPDT. The Series 1640 floating contact null switch is not snap acting and switches at two preset points with no action between them, so reserve it for applications that need that null band. The large diaphragm model lists a 15 amp maximum current load, which matters when the switch will drive a small electrical load directly.
Confirm the media and approvals. Dwyer lists air and non-combustible, compatible gases as the service for the single and dual switch and the large diaphragm model, so verify media compatibility on each listing before specifying. When comparing Dwyer Pressure Controls, note that the Series 1800 low differential pressure switch carries UL and CSA listings and FM approval, while approvals for other models should be confirmed on their own listings. Finally, remember that the panel mount nut is a regulator accessory rather than a switch, and the Series MPR regulator models differ by media: air models are self relieving and air/water models are nonrelieving.
Frequently Asked Questions
What pressure ranges do Dwyer pressure switches cover?
Dwyer Pressure Controls in this category include switches with ranges of .15 to 1.5 inch w.c., 0.20 to 1.0 inch w.c., 1.0 to 4.0 inch w.c., and .3 to 1.0 inch w.c. Each range belongs to a specific model, so match the range to the application before ordering.
What is a Dwyer null switch used for?
A Dwyer null switch, such as the Series 1640 floating contact model, uses a single pole, double throw floating contact that is not snap acting. As the diaphragm moves, it switches at two preset points with no switching action between them. The design suits applications that need a null band.
What media can Dwyer pressure switches handle?
Dwyer lists air and non-combustible, compatible gases as the service for the single and dual pressure switch and the large diaphragm pressure switch. Dwyer Pressure Controls vary by model, so confirm media on the listing for the exact switch.
Are Dwyer low differential pressure switches UL listed?
The Dwyer Series 1800 low differential pressure switch is UL and CSA listed and FM approved. The Series 1800 also lists 2% repeatability for general industrial service. Confirm approvals on the listing for any other Dwyer pressure control.
What does the Dwyer panel mount nut fit?
The panel mount nut in this Dwyer Pressure Controls category is an accessory for the Series MPR miniature pressure regulator. Dwyer describes that regulator as a compact unit for compressed air or air/water, with air models that are self relieving and air/water models that are nonrelieving. Confirm the regulator model before ordering the nut.